Device Trial Radar · NCT07207005
Comparison of Wear Between Two Dual-mobility Acetabular Cups in Patients Undergoing Total Hip Arthroplasty
Last checked: Nov 20, 2026Latest source record: Aug 20, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
96
Planned (sponsor's estimate)
Start
Jul 30, 2026
Primary completion
Dec 31, 2038
Study completion Dec 31, 2038
Sponsor
- Lead sponsor
- GCS Ramsay Santé pour l'Enseignement et la RechercheAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Oct 3, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Single (participant)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 55 years, up to 80 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
In 2022, data from the UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) indicated that Total Hip Replacement (THR) is the most commonly performed orthopaedic joint surgery. The NJR has observed that between 10 and 20% of hip implants require revision within the first 10 years. The main reasons for these revisions include implant fractures, joint incompatibility, aseptic loosening, dislocation and wear of the polyethylene (PE) insert. To address this problem, highly cross-linked polyethylene (HXLPE) inserts have been developed. Cross-linking helps to limit wear on polyethylene prostheses in total hip arthroplasty. However, there are concerns about the loss of elasticity of HXLPE and oxidation after implantation. A new generation of inserts based on highly cross-linked polyethylene (irradiation dose ≥100 Kgy), enriched with vitamin E, has been developed. This PE, called ECIMA, was developed to maintain mechanical properties, minimise PE wear and improve long-term oxidation resistance. In the HAS evaluation report on highly cross-linked polyethylene inserts dated 24 January 2023, data from the literature show less wear of highly cross-linked polyethylene compared to conventional polyethylene. Nevertheless, the use of highly cross-linked polyethylene is not yet the gold standard. Furthermore, the data in the literature mainly concern single-mobility cups but not double-mobility cups. Finally, new imaging protocols now make it possible to assess the wear of prosthesis materials more accurately. In this context, it seems appropriate to conduct a French study comparing double-mobility cups containing highly cross-linked polyethylene or conventional polyethylene inserts.
Conditions
- Hip Arthroplasty Replacement
Interventions
ECIMA CORINDevice
Mobile cup (Corin) made of highly cross-linked PE doped with vitamin E (ECIMA, Corin).
CORINDevice
Mobile cupule (Corin) is made of conventional PE
Primary outcomes
What the sponsor says the trial is designed to measure.
- Femoral head penetration into the acetabulumTime frame: Year 5
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Hôpital Privé Jean Mermoz
Lyon, France, France · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.