Detection of Sleep Stages and Arousals Using Neural Network Classifiers

Validation of Smart Mask V1 System: A Clinical Study Comparing a System for Detecting Sleep Stages and Arousals to Manual Polysomnography Scoring

Last checked: Nov 19, 2026Latest source record: Sep 16, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

72

Actual

Start

Oct 4, 2025

Primary completion

Dec 21, 2025

Study completion Dec 21, 2025

Sponsor

Lead sponsor
Pathway Medtech, LLC.Not on our public-company list
Sponsor type
Industry
First posted
Aug 22, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Non randomized
Model
Single group
Masking
None
Primary purpose
Supportive care
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

The objective of this clinical study is to evaluate the accuracy of the Smart Mask V1 System (herein 'Smart Mask') in measuring sleep stages-Stage N1/N2, Stage N3, Rapid Eye Movement (herein 'REM'), and WAKE-arousals, and the Arousal Index in adults diagnosed with sleep-disordered breathing, such as obstructive sleep apnea (herein 'OSA'). The Smart Mask operates in concert with a Wireless Access Module (herein 'WAM'), which is connected to a standard positive air pressure (herein 'PAP') device used in the treatment of OSA. Collectively the Smart Mask and WAM operate neural network classifier algorithms to determine sleep stages, arousals, and Arousal Index. These algorithms are coded into an embedded software system called the Sleep Staging and Arousal Module (herein 'SSAM') that operates directly on the WAM. The SSAM processes the following parameters, collected while the participant is asleep: 1) instantaneous values of pulse rate, determined from embedded optical sensors within the Smart Mask that measure photoplethysmogram waveforms (herein 'PPG'); and 2) full-resolution flow waveforms measured by sensors within the PAP device and retrieved by the WAM. During the study, volunteer participants (preferably those with OSA) will undergo an overnight sleep study in sleep testing facility located at three separate clinical sites. The test device (comprising the SSAM operating on the WAM) will retrospectively determine sleep stages and arousals, after the participant's sleep session has concluded. To evaluate the accuracy of the test device, its values of sleep stages, arousals, and Arousal Index will be compared to those parameters determined by polysomnography (herein 'PSG', a recognized gold-standard reference) and EnsoSleep (a FDA-cleared predicate device, and specifically a software package that uses artificial intelligence (AI) to determine sleep stages and arousals). Each volunteer participant will wear an FDA-cleared wrist-worn pulse oximeter called the 'Checkme O2' which generates data (specifically PPG waveforms and values of SpO2 and pulse rate) for the EnsoSleep cloud-based software platform. The main questions this study aims to answer are: * Can the Smart Mask accurately identify different sleep stages compared to the EnsoSleep device? * Can the Smart Mask accurately identify sleep arousals and calculate the Arousal Index compared to the EnsoSleep device? Answers to these questions will be derived through comparative statistical analysis involving the test device, the gold-standard PSG reference, and the FDA-cleared predicate device, employing methodologies similar to those used in the validation of the EnsoSleep. The study will include two cohorts. The first cohort will include approximately 75 participants from a single clinical site and will be used for device training purposes. The second cohort will consist of approximately 72 different participants, and will be used to validate the test device. Participants in the second cohort will be distributed roughly evenly across two separate clinical sites.

Conditions

  • Sleep Disordered Breathing (SDB)
  • Sleep Apnea

Interventions

  • SSAMDevice

    Embedded software featuring neural-network classifiers designed to detect and classify sleep stages (N1/N2, N3, REM, Wake), autonomic arousals, and an Arousal Index based on data (specifically instantaneous pulse rate and full-resolution flow waveforms) collected during PAP therapy.

  • PolysomnographyDiagnostic test

    Polysomnography (PSG) is an overnight, in-laboratory diagnostic procedure that records multiple physiological parameters during sleep. It typically includes monitoring of brain activity (EEG), eye movements (EOG), muscle activity (EMG), heart rhythm (ECG), respiratory effort, airflow, oxygen saturation, and body position. PSG is used to evaluate sleep architecture, identify sleep stages, detect arousals, and diagnose sleep disorders such as sleep apnea. The collected data are analyzed manually by trained sleep technologists following standardized scoring criteria.

  • EnsoSleepDevice

    EnsoSleep is software-only medical device intended for use by physicians to assess sleep quality and aid in the diagnosis of sleep disorders. The software analyzes physiological signals and automatically scores sleep study results, including respiratory, sleep staging, arousal and movement events. Automatically scored events and physiological signals are analyzed, displayed, and summarized for review by clinicians.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Agreement Between Smart Mask V1 System and EnsoSleep in Detecting Arousals and Arousal IndexTime frame: One overnight sleep study session (6-8 hours per participant)

Locations

3 sites in 1 country. Site status is shown where the registry gives one.

  • Peninsula Sleep Center

    Burlingame, California

  • Amnova Research

    Irvine, California

  • ACTRI Center for Clinical Research

    La Jolla, California

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.