Evaluation of Cranial Flap Fixation With Montage Flowable Settable Bone Paste

Last checked: Nov 20, 2026Latest source record: Aug 5, 2025 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruitingPivotal-lookingRandomized with 100 participants. This is a heuristic, not a regulatory label.

Status

Not yet recruiting

Enrollment

100

Planned (sponsor's estimate)

Start

Mar 2026

Primary completion

Dec 2027

Study completion Dec 2027

Sponsor

Lead sponsor
Abyrx, Inc.Not on our public-company list
Sponsor type
Industry
First posted
Aug 5, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Single (participant)
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Montage Flowable Settable Bone Paste is a self-setting calcium phosphate cement indicated for use in the repair of neurosurgical burr holes, contiguous craniotomy cuts and other cranial defects with a surface area no larger than 25cm2. It is also intended to be used for the fixation of cranial bone flaps following craniotomy. The MONTAGE Flowable device comprises two separate components of paste-like consistency containing granular calcium phosphate, calcium stearate, vitamin E acetate, a triglyceride, polyalcohols and a mixture of a lactide-diester and polyester-based polymers. When mixed together in the applicator tip, the components of the MONTAGE Flowable device form a cohesive paste-like material that adheres to the bone surface and remains in place following application. The resulting hardened, resorbable material is primarily calcium phosphate. The components must be mixed immediately prior to use.

Conditions

  • Cranial Bone
  • Post-operative Complications
  • Cranial Fixation
  • Cranioplasty
  • Adhesive Bone Cement

Interventions

  • Metallic fixation hardwareDevice

    Control

  • Cranial flap placement and fixation using only Montage Flowable Settable Bone PasteDevice

    Experimental

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Cranial flap immobilityTime frame: 12 months

Locations

No sites are listed on the registry yet.

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.