Device Trial Radar · NCT07083908
A Comparison of THD® Anopress With High Resolution Anorectal Manometry
Last checked: Nov 20, 2026Latest source record: Apr 16, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
53
Actual
Start
Mar 1, 2025
Primary completion
Nov 11, 2025
Study completion Nov 11, 2025
Sponsor
- Lead sponsor
- King's College Hospital NHS TrustAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jul 24, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- Single (investigator)
- Primary purpose
- Diagnostic
- FDA-regulated device
- No
- Who can join
- Female only, from 18 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
Currently, high resolution anorectal manometry (HDARM) is used as gold standard to measure anal sphincter pressures in women who have sustained a third or fourth degree perineal tears (obstetric anal sphincter injuries). This test is performed to help advise patients on future pregnancies or deliveries. However, HDRM catheters are very expensive and they also need to be performed in a dedicated procedure room. THD® Anopress in comparison is a lightweight, portable device which has a comparatively shorter investigation time and is more cost- effective. However, although THD® Anopress is currently used in the colorectal population, there is currently no validated research that compares the measurements obtained by HDARM with that of THD® Anopress with women with a history of obstetric anal sphincter injuries. The primary aim of this study is to compare pressure measurements from HDARM to that of THD® Anopress in women with obstetric anal sphincter injuries.
Conditions
- Obstetric Anal Sphincter Injury
Interventions
THD® Anopress (Sensyprobe) firstDevice
Anorectal manometry with THD® Anopress (Sensyprobe) first then with High Resolution Anorectal Manometry (Laborie)
High Resolution Anorectal Manometry firstDevice
Anorectal manometry with High Resolution Anorectal Manometry (Laborie) first followed by THD® Anopress (Sensyprobe)
Primary outcomes
What the sponsor says the trial is designed to measure.
- Main voluntary squeeze incrementTime frame: Day 1
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Kings College Hospital
London, United Kingdom
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.