Device Trial Radar · NCT07076277
Visual Outcomes in Patients Contralaterally Implanted With PanOptix Pro and Clareon Vivity Compared to Bilateral Implantation of PanOptix Pro
Last checked: Nov 19, 2026Latest source record: Sep 22, 2025 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Enrolling by invitation
Enrollment
346
Planned (sponsor's estimate)
Start
Aug 5, 2025
Primary completion
Aug 1, 2026
Study completion Dec 1, 2026
Sponsor
- Lead sponsor
- Brian ShaferAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jul 22, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Quadruple (participant, care provider, investigator, outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Title: Visual Outcomes in Patients Contralaterally Implanted with PanOptix Pro and Clareon Vivity Compared to Bilateral Implantation of PanOptix Pro Sponsor: Brian Shafer, MD, Shafer Vision Institute Objective: To compare visual outcomes and patient-reported satisfaction in cataract patients receiving either: Contralateral implantation (PanOptix Pro in one eye, Clareon Vivity in the other) Bilateral PanOptix Pro implants Key hypotheses: Contralateral implantation is non-inferior for binocular best-corrected distance visual acuity (BCDVA) at 4 m. Contralateral implantation yields superior visual disturbance outcomes (less halo, glare, starburst). Design: Prospective, randomized, double-masked, two-arm, multicenter study N = 346 subjects (173 per arm) 5 surgeons across 4 sites All patients undergo bilateral phacoemulsification aiming for emmetropia Randomized 1:1 to: Arm 1: PanOptix Pro (dominant eye) + Clareon Vivity (non-dominant eye) Arm 2: Bilateral PanOptix Pro Surgical Details: Femtosecond laser optional Second eye surgery ≤4 weeks after first Toric IOLs or arcuate incisions for residual astigmatism ≤0.50 D Biometry with ARGOS, IOLMaster 700, or Lenstar Toric alignment with ORA, Callisto, etc. Assessments: Visual acuity at 4 m, 66 cm, 40 cm, 33 cm in photopic and mesopic conditions Defocus curves, contrast sensitivity (with/without glare) Manifest refraction Patient-reported outcomes via IOLSAT and QUVID questionnaires Masking: subjects and assessors unaware of IOL assignments Endpoints (at 3 months): Primary: Binocular BCDVA (4 m) Secondary: DCIVA, DCNVA, UDVA, UIVA, UNVA, defocus curves, refractive outcomes, visual disturbance scores Exploratory: Mesopic VA, low contrast VA, contrast sensitivity, satisfaction scores Eligibility Criteria: Adults with bilateral age-related cataracts Plan for bilateral phacoemulsification Expected postop monocular BCDVA ≤0.1 logMAR (20/25) Residual astigmatism ≤0.50 D Exclusions include corneal pathology, macular disease, glaucoma, prior ocular surgery, amblyopia, severe dry eye, high HOA (\>0.6 um), monovision preference, active infection/inflammation, pregnancy Statistics: Non-inferiority margin: 0.1 logMAR Superiority testing for visual disturbances Step-down testing hierarchy for primary and secondary outcomes Sample size powered for 80% at α=0.05, accounting for 10% dropout Two-proportion Z-tests for dysphotopsia rates Safety Monitoring: Adverse Events (AEs) and Serious Adverse Events (SAEs) captured Definitions, severity grading, and reporting procedures specified Protocol deviations documented and reported per IRB requirements Data Handling: Data anonymized via subject numbers Stored securely (locked cabinets, password-protected systems) Study registered at ClinicalTrials.gov Visit Schedule: Screening: Consent, eligibility, history 1st \& 2nd Eye Surgery Visits 3-Month Post-Op Visit: Comprehensive visual assessments, questionnaires, AE review
Conditions
- Cataract
- Multifocal Intraocular Lens
Interventions
Clareon PanOptix Pro and Clareon Vivity Intraocular LensDevice
Bilateral cataract surgery with contralateral implantation: Alcon Clareon PanOptix Pro (or PanOptix Pro Toric) intraocular lens in one eye and Alcon Clareon Vivity (or Vivity Toric) intraocular lens i
Clareon PanOptix Pro Intraocular LensesDevice
Bilateral cataract surgery with implantation of Alcon Clareon PanOptix Pro (or PanOptix Pro Toric) intraocular lenses in both eyes. All surgeries target emmetropia with residual astigmatism ≤0.50 diopters using toric IOLs or arcuate incisions as needed.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Binocular Best-Corrected Distance Visual Acuity (BCDVA) at 4 metersTime frame: 3 months post-operative visit
Locations
5 sites in 1 country. Site status is shown where the registry gives one.
VIP Eye Care
Baltimore, Maryland
Vance Thompson Vision
Alexandria, Minnesota
Vance Thompson Vision
Bozeman, Montana
2 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.