All In MedTech

Device Trial Radar · NCT07058584

Synergistic Effects of Aerobic Exercise and Repetitive Transcranial Magnetic Stimulation

Synergistic Effects of Aerobic Exercise and Repetitive Transcranial Magnetic Stimulation on Brain Connectivity and Pain Sensitivity

Last checked: Nov 19, 2026Latest source record: Jun 2, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

20

Actual

Start

Apr 1, 2025

Primary completion

May 30, 2026

Study completion May 31, 2026

Sponsor

Lead sponsor
Aalborg UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Jul 10, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 60 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

Participants attend two sessions, one week apart, as part of a randomized crossover study involving either an active or sham intervention. Both sessions follow identical procedures, except for the TMS intervention. Each session includes: three pain pressure threshold measurements, two TMS-EEG recordings, 30 minutes of moderate-intensity exercise on a stationary bike, and two resting-state EEG recordings. Repetitive TMS is administered as an active intervention in one session and as a sham in the other, and more.

Conditions

  • Aerobic Exercise
  • Repetitive Transcranial Magnetic Stimulation (rTMS)

Interventions

  • repetitive Transcranial Magnetic StimulationDevice

    Repetitive transcranial magnetic stimulation (rTMS) is administered using a figure-of-eight coil from MagVenture positioned over the left primary motor cortex (M1) in an anteroposterior direction. High-frequency rTMS is delivered at 10 Hz, consisting of 100 trains of 10-second duration (3000 pulses), with 20-second inter-train intervals, at \~90% of resting motor threshold (RMT) depending on participant tolerance and TMS-EEG brain response.

  • Sham repetitive Transcranial Magnetic StimulationDevice

    This intervention involves high-frequency repetitive transcranial magnetic stimulation (rTMS) applied over the primary motor cortex (M1), using a figure-of-eight coil. In the sham condition, the same coil is used, but it is oriented away from the scalp at an angle that prevents effective magnetic stimulation of the brain, while still producing similar auditory and tactile sensations. This allows participants to remain blinded to the intervention type, maintaining the single-blind nature of the study. The active stimulation is delivered at 10 Hz, comprising 30 trains of 10 seconds (9900 milliseconds)(3000 pulses in total), with 20-second inter-train intervals, at \~110% of the individual's resting motor threshold (rMT). Stimulation is delivered while the participant is seated at rest, and the full rTMS protocol takes approximately 15 minutes to complete.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Cortical connectivityTime frame: Day 1
  2. Cortical connectivityTime frame: Day 2

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Aalborg University

    Gistrup, Denmark

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.