The Study Seeks to Determine Potential Correlations Between Ventilation and Hematological Alterations, Contributing to a Better Understanding of Its Physiological Effects and Optimizing Patient Management in Critical Care Settings.

Impact of Mechanical Ventilation on Hematological Parameters in Pediatric Patients With Sepsis

Last checked: Nov 19, 2026Latest source record: Jun 22, 2025 (this record)Source: ClinicalTrials.govMethods & limitations

Not yet recruiting

Status

Not yet recruiting

Enrollment

60

Planned (sponsor's estimate)

Start

Apr 2026

Primary completion

Apr 2027

Study completion May 2027

Sponsor

Lead sponsor
Assiut UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Jun 22, 2025

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
All sexes, from 1 month, up to 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The study seeks to determine potential correlations between ventilation and hematological alterations, contributing to a better understanding of its physiological effects and optimizing patient management in critical care settings.

Conditions

  • Pediatric Sepsis-induced Multiple Organ Dysfunction Syndrome

Interventions

  • complete blood testsDiagnostic test

    Complete Blood Count (CBC): Using automated hematology analyzers to measure various blood cell parameters. * C-Reactive Protein (CRP): Quantitative analysis using immunoturbidimetric assay. * Erythrocyte Sedimentation Rate (ESR): Measured using the Westergren method. * Coagulation profile: * Prothrombin Time (PT): Using thromboplastin reagents and automated coagulation analyzers. * Activated Partial Thromboplastin Time (aPTT): Using phospholipid-based reagents and automated analyzers. * International Normalized Ratio (INR): Calculated from PT results. * Bleeding Time: Ivy method or template bleeding time. * Liver function tests: Including ALT, AST, ALP, bilirubin using spectrophotometric methods. * Kidney function tests: Creatinine and BUN using enzymatic methods.

  • mechanical ventilation (MV)Device

    Mechanical Ventilation Parameters * \- Ventilation Mode: Ventilator settings will record modes such as volume-controlled ventilation or synchronized intermittent mandatory ventilation (SIMV), which deliver breaths based on patient needs. * Tidal Volume: Measured in milliliters per kilogram of predicted body weight. Tidal volume settings aim to optimize oxygenation while minimizing lung injury risks by adhering to evidence-based limits (\<6 mL/kg). * Positive End-Expiratory Pressure (PEEP): PEEP levels will be recorded in cmH₂O to prevent alveolar collapse and improve oxygenation. Adjustments will balance oxygenation benefits with potential risks like reduced venous return or lung overdistension. * Fraction of Inspired Oxygen (FiO₂): FiO₂ values will be documented as decimals, starting at 1.0 (100% oxygen) and adjusted downward based on patient oxygenation needs.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. identify correlations between mechanical ventilation and hematological alterations in pediatric patients diagnosed with sepsis.Time frame: Baseline

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Assiut University Children's Hospital

    Asyut, Egypt

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.