Device Trial Radar · NCT07030114
The Study Seeks to Determine Potential Correlations Between Ventilation and Hematological Alterations, Contributing to a Better Understanding of Its Physiological Effects and Optimizing Patient Management in Critical Care Settings.
Last checked: Nov 19, 2026Latest source record: Jun 22, 2025 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Not yet recruiting
Enrollment
60
Planned (sponsor's estimate)
Start
Apr 2026
Primary completion
Apr 2027
Study completion May 2027
Sponsor
- Lead sponsor
- Assiut UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jun 22, 2025
Design
- Study type
- Observational
- FDA-regulated device
- No
- Who can join
- All sexes, from 1 month, up to 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The study seeks to determine potential correlations between ventilation and hematological alterations, contributing to a better understanding of its physiological effects and optimizing patient management in critical care settings.
Conditions
- Pediatric Sepsis-induced Multiple Organ Dysfunction Syndrome
Interventions
complete blood testsDiagnostic test
Complete Blood Count (CBC): Using automated hematology analyzers to measure various blood cell parameters. * C-Reactive Protein (CRP): Quantitative analysis using immunoturbidimetric assay. * Erythrocyte Sedimentation Rate (ESR): Measured using the Westergren method. * Coagulation profile: * Prothrombin Time (PT): Using thromboplastin reagents and automated coagulation analyzers. * Activated Partial Thromboplastin Time (aPTT): Using phospholipid-based reagents and automated analyzers. * International Normalized Ratio (INR): Calculated from PT results. * Bleeding Time: Ivy method or template bleeding time. * Liver function tests: Including ALT, AST, ALP, bilirubin using spectrophotometric methods. * Kidney function tests: Creatinine and BUN using enzymatic methods.
mechanical ventilation (MV)Device
Mechanical Ventilation Parameters * \- Ventilation Mode: Ventilator settings will record modes such as volume-controlled ventilation or synchronized intermittent mandatory ventilation (SIMV), which deliver breaths based on patient needs. * Tidal Volume: Measured in milliliters per kilogram of predicted body weight. Tidal volume settings aim to optimize oxygenation while minimizing lung injury risks by adhering to evidence-based limits (\<6 mL/kg). * Positive End-Expiratory Pressure (PEEP): PEEP levels will be recorded in cmH₂O to prevent alveolar collapse and improve oxygenation. Adjustments will balance oxygenation benefits with potential risks like reduced venous return or lung overdistension. * Fraction of Inspired Oxygen (FiO₂): FiO₂ values will be documented as decimals, starting at 1.0 (100% oxygen) and adjusted downward based on patient oxygenation needs.
Primary outcomes
What the sponsor says the trial is designed to measure.
- identify correlations between mechanical ventilation and hematological alterations in pediatric patients diagnosed with sepsis.Time frame: Baseline
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Assiut University Children's Hospital
Asyut, Egypt
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.