Device Trial Radar · NCT07014098
Robot-Aided Off-Axis Neuromuscular Training for Knee OA
Last checked: Nov 19, 2026Latest source record: Nov 16, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Not yet recruiting
Enrollment
36
Planned (sponsor's estimate)
Start
Jan 1, 2027
Primary completion
Oct 31, 2029
Study completion Jan 2030
Sponsor
- Lead sponsor
- University of Maryland, BaltimoreAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jun 10, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Double (participant, outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 45 years, up to 85 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Although the primary knee motion occurs in flexion/extension, the frontal and transverse (off-axis) knee motions are smaller but crucial for maintaining joint stability and normal knee loading. Altered kinematics and neuromuscular control in off-axis knee motions have been reported in patients with knee osteoarthritis (OA), which are associated with excessive knee loading and the progression of knee OA. However, traditional rehabilitative treatments for people with knee OA and existing exercise equipment often focus on sagittal plane movement. Probably due to the technical limitations, there is a lack of convenient and effective equipment/method to train patients with knee OA in off-axis (frontal and transverse) planes. The purpose of this study is to use a robot-aided elliptical training device to measure knee neuromechanical properties and to improve neuromuscular control in off-axis knee motions, aiming for joint de-loading and pain reduction for individuals with knee OA.
Conditions
- Osteoarthritis of Knee
Interventions
Robot-Aided Off-Axis Neuromuscular TrainingDevice
A novel custom-designed elliptical trainer is developed, and its footplates are robot-controlled to be moved in four off-axis directions (sliding in/out, pivoting in/out; corresponding to knee valgus/varus, internal rotation/external rotation). Before the training, off-axis neuromechanical assessments will be conducted to determine which specific off-axis direction (valgus, varus, internal rotation, external rotation, or combination of the off-axis directions) has neuromechanical deficits. During the evaluation-based and subject-specific neuromuscular training, the different training modes will be conducted progressively from regular stepping, footplate position control, spring mode, perturbation, to slippery mode.
Traditional elliptical regular steppingDevice
traditional elliptical regular stepping
Primary outcomes
What the sponsor says the trial is designed to measure.
- Peak knee adduction momentTime frame: Baseline, immediately after the 5-week training, and follow-up evaluation 8-week post-training
- Knee painTime frame: Baseline, immediately after the 5-week training, and follow-up evaluation 8-week post-training
Locations
No sites are listed on the registry yet.
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.