All In MedTech

Device Trial Radar · NCT06993571

Cerebellar Transcranial Alternating Current Stimulation (tACS) to Modulate Parkinson's Disease Tremor

Closed-loop Phase-adaptive Cerebellar Transcranial Alternating Current Stimulation (tACS) to Modulate Activity in the Cerebello-thalamo-cortical Network to Reduce Parkinson's Disease Tremor

Last checked: Nov 19, 2026Latest source record: Sep 1, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

10

Planned (sponsor's estimate)

Start

Apr 16, 2025

Primary completion

Mar 31, 2027

Study completion Dec 31, 2027

Sponsor

Lead sponsor
Universitätsklinikum Hamburg-EppendorfAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
May 29, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Crossover
Masking
Double (participant, outcomes assessor)
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Parkinson's disease (PD) is a prevalent neurodegenerative disorder characterized by different motor symptoms, including tremor, which is particularly difficult to manage. Common treatments, such as dopaminergic therapy, can have limitations in efficacy. Recent advancements in non-invasive brain stimulation, specifically phase-adaptive transcranial alternating current stimulation (tACS), offer a promising approach to reduce PD tremor. In the current project, a newly developed closed-loop system delivers precisely synchronized cerebellar tACS by aligning stimulation with the intrinsic hand tremor signal. The study will assess the efficacy of this novel approach to reduce hand tremor in PD patients.

Conditions

  • Parkinson's Disease (PD)
  • Tremor

Interventions

  • Active-tACSDevice

    30 seconds of closed-loop tACS at 2-4 mA, with 6 alternating phase alignments and 1-3 repetitions. Phase alignment is adjusted to the patient's tremor frequency and rhythm in real time. Administered using the neuroConn LOOPIT device and 2 electrodes placed on the cerebellum and jaw, with an area of 5x5 and 5x7 respectively. The stimulation begins with a 3-second ramp-up and ends with a 3-second ramp-down.

  • Sham-tACSDevice

    30 seconds of tACS at 0 mA and 1-3 repetitions. Administered using the neuroConn LOOPIT device and 2 electrodes placed on the cerebellum and jaw, with an area of 5x5 and 5x7 respectively. The sham protocol begins with a 3-second ramp-up and ends with a 3-second ramp-down.

  • Unlocked-tACSDevice

    30 seconds of open-loop tACS at 2-4 mA, with no phase alignments and 1-3 repetitions. Administered using the neuroConn LOOPIT device and 2 electrodes placed on the cerebellum and jaw, with an area of 5x5 and 5x7 respectively. The stimulation begins with a 3-second ramp-up and ends with a 3-second ramp-down.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change in tremor amplitudeTime frame: During the stimulation

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Universitätsklinikum Hamburg-Eppendorf

    Hamburg, Free and Hanseatic City of Hamburg, Germany · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.