Device Trial Radar · NCT06957912
Transcutaneous Auricular Vagus Nerve Stimulation and Quality of Recovery After Major Noncardiac Surgery
Last checked: Nov 20, 2026Latest source record: Jun 3, 2025 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
320
Planned (sponsor's estimate)
Start
May 13, 2025
Primary completion
Aug 2026
Study completion Sep 2026
Sponsor
- Lead sponsor
- Peking University First HospitalAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- May 6, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Quadruple (participant, care provider, investigator, outcomes assessor)
- Primary purpose
- Prevention
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years, up to 85 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Transcutaneous auricular vagus nerve stimulation (taVNS) is a novel non-invasive neuromodulation technique. Existing evidence suggested that taVNS improves pain management, sleep quality, inflammatory responses, and gastrointestinal recovery after surgery. This study is designed to test the hypothesis that perioperative use of taVNS may improve quality of recovery in patients after major noncardiac surgery.
Conditions
- Vagus Nerve Stimulation
- Transcutaneous Electric Nerve Stimulation
- Noncardiac Surgery
- Quality of Recovery
Interventions
Transcutaneous auricular vagus nerve stimulationDevice
Transcutaneous auricular vagus nerve stimulation is performed using earphone-shaped stimulators (tVNS501, Ruishenan Medical Device, Inc. JiangSu, China) on the left tragus areas of the outer ear for a total of 30 min. Using parameters we have identified through systematic review, electrical stimulation (pulse width: 200-300 μs; frequency: 25 Hz; duty cycles: 50%) is initiated at 200% perceptual threshold (PT) which means the minimum amount of electricity required to perceive electrical stimulation on the skin described as a pricking or tingling sensation. All conscious patients will be told they may or may not feel any sensation from the stimulation. The stimulation will be performed between 15:00 and 17:00 on the first day before surgery, at least 30 minutes before the start of surgery and between 08:00 and 10:00 on the first to third day after surgery.
Sham stimulationDevice
Sham stimulation is performed using earphone-shaped stimulators (tVNS501, Ruishenan Medical Device, Inc. JiangSu, China) on the left tragus areas of the outer ear for a total of 30 min. Using parameters we have identified through systematic review, electrical stimulation (pulse width: 200-300 μs; frequency: 25 Hz; duty cycles: 50%) is initiated at 200% perceptual threshold (PT) which means the minimum amount of electricity required to perceive electrical stimulation on the skin described as a pricking or tingling sensation. And the current will be automatically switched off after 15 s. All conscious patients will be told they may or may not feel any sensation from the stimulation. The stimulation will be performed between 15:00 and 17:00 on the first day before surgery, at least 30 minutes before the start of surgery and between 08:00 and 10:00 on the first to third day after surgery.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Quality of recovery scores at 24 hours after surgeryTime frame: At 24 hours after surgery
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Peking University First Hospital
Beijing, Beijing Municipality, China · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.