Refractory Chronic Cluster Headache: Exploring the Potential of Repetitive Transcranial Magnetic Stimulation

Evaluating Repetitive Transcranial Magnetic Stimulation for Refractory Chronic Cluster Headache Prevention: Insights From a Randomised Crossover Pilot Trial

Last checked: Nov 20, 2026Latest source record: Apr 8, 2025 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

8

Actual

Start

Dec 21, 2023

Primary completion

May 31, 2024

Study completion May 31, 2024

Sponsor

Lead sponsor
Hospital Universitario La PazAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Apr 8, 2025

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Crossover
Masking
Quadruple (participant, care provider, investigator, outcomes assessor)
Primary purpose
Prevention
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The goal of this clinical trial is to learn if drug ABC works to treat severe asthma in adults. It will also learn about the safety of drug ABC. The main questions it aims to answer are: Does Transcranial Magnetic Stimulation lower the number of attacks per week in patients with refractory cluster headache ? Researchers will compare transcranial magnetic stimlation to a sham stimulation (a look-alike stimulation) to see if it works to prevent attacks of cluster headache. Participants will: Recieve stimulation for 10 minutes for 10 consecutive working days in 2 periods of time, separated by a 1 month washout period. Visit the clinic for each treatment day. Keep a diary of their symptoms and the number of times they use a rescue medication

Conditions

  • Refractory Chronic Cluster Headache

Interventions

  • Repetitive Transcranial Magnetic StimulationDevice

    Stimulation sessions were performed using a YINGCHI M-100 Ultimate device with liquid-cooled figure-8 coils. Patients attended 10-minute sessions daily for 10 consecutive working days. For rTMS, stimulation was delivered at an excitatory frequency of 10 Hz, targeting the M1, contralateral to the side of pain in the facial region. Each session consisted of the following steps. * 10 series: 60 pulses per series (600 pulses in total). * Rest intervals: 60 seconds between series. * Intensity: 70% of the resting motor threshold (RMT). RMT was determined using single-pulse stimulation over the M1 region controlling the abductor pollicis brevis muscle, localized via neuronavigation. The threshold was de-fined as the lowest stimulator intensity producing a motor-evoked potential amplitude \>50 µV in at least 5 of 10 trials.

  • Sham StimulationDevice

    Sham Stimulation: The same device and protocol used for intervention protocol with Repetitive Transcranial Magnetic Stimulation were used for sham stimulation, but no active stimulation was delivered. The equipment produced identical sounds and appearances, thereby ensuring blinding.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Reduction in number of attacks per weekTime frame: From enrollment to the end to follow up period, at 3 months after last treatment period (week 8)

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Hospital Universitario La Paz

    Madrid, Madrid, Spain

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.