All In MedTech

Device Trial Radar · NCT06746922

Intermittent Theta Burst Stimulation in Fibromyalgia Syndrome

The Effect of Intermittent Theta Burst Stimulation to the Primary Motor Cortex on Pain Intensity, Pain Catastrophizing, Quality of Life and Mood in Fibromyalgia Patients

Last checked: Nov 20, 2026Latest source record: Mar 18, 2025 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

30

Planned (sponsor's estimate)

Start

Mar 13, 2025

Primary completion

Feb 1, 2027

Study completion Apr 1, 2027

Sponsor

Lead sponsor
Izmir Katip Celebi UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Dec 24, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Double (participant, outcomes assessor)
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 65 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Research on repetitive transcranial magnetic stimulation therapy in fibromyalgia syndrome (FMS) is increasing rapidly. High-frequency rTMS administration to FMS patients is reported to restore intracortical facilitation and provide successful pain relief. This finding supports restoration of cortical stimulation as one of the possible mechanisms of action for rTMS. One treatment protocol is intermittent theta burst stimulation (iTBS, a variant of excitatory rTMS). Although there are many treatment protocols, there are few widely accepted treatment schemes in the literature. In fibromyalgia syndrome, there is no study in the literature. It was planned to include at least 30 patients aged 18-65 years who were admitted to İzmir Katip Çelebi University Atatürk Training and Research Hospital Physical Medicine and Rehabilitation Outpatient Clinic or hospitalized in the ward and diagnosed with fibromyalgia syndrome according to the 2016 criteria. This study has a prospective, parallel group, randomized, sham-controlled study design. A total of 30 fibromyalgia patients will be randomized into 2 groups and will receive a total of 10 sessions of transcranial magnetic stimulation to the primary motor cortex with intermittent theta bust stimulation technique or sham application. Patients will continue their current fibromyalgia treatment.Numeric Rating Scale-pain intensity (NRS-pain), revised Fibromyalgia Impact Questionnaire (FIQR), Pain Catastrophizing Scale (PCS), Hospital Depression Anxiety Scale (HADS) will be used in the evaluation of the patients.

Conditions

  • Fibromyalgia
  • Transcranial Magnetic Stimulation Repetitive
  • Pain

Interventions

  • Intermittent theta-burst stimulationDevice

    Neuro-MS/D (Neurosoft) rTMS device will be used for stimulation with an angulated figure-of-eight coil. Neuronavigation system will be used to determine the application site. Before each session, active motor threshold (aMT) will be determined by obtaining a motor evoked potential with an amplitude of \>200μV in the EMG recording of the first dorsal interosseous muscle (FDI), which is slightly contracted (10-20% of maximum contraction) in at least five out of 10 stimuli delivered to the primary motor cortex. The handle will be held at a 45° angle to the sagittal plane, pointing backwards and laterally to create posterior-anterior current flow in the brain. The stimulation parameters are as follows: Parameters: Stimulation type:Burst Stimulus amplitude (% MT): 80 Burst frequency in sequence (Hz):5 Pulse frequency within burst (Hz):50 Number of bursts in the sequence: 10 Number of series:20 Interval between sequences: 8 sec Total time: 3min 47sec Total number of pulses: 600

  • Sham Intermittent theta-burst stimulationDevice

    In the sham application, the probe of the transcranial magnetic stimulation device will be placed in the vertical position and held perpendicular to the vertex and applied at an ineffective dose so that the patient hears the same sound. In order for the device to produce the same sound and warning sounds as the active application, it will be operated at the lowest operating power of 1 power. In the device operating at this power, there is no possibility of any warning due to the upright position of the probe.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change from baseline in the Numeric Rating ScaleTime frame: (1) at the beginning of the treatment (T0), (2) at the 1st week (T1), (3) at the 2nd week (T2), (4) four weeks after the end of the treatment (T3).

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Izmir Katip Çelebi University Atatürk Training and Research Hospital

    Izmir, Karabaglar, Turkey (Türkiye) · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.