Total Knee Arthroplasty Inserted With Patient Specific or Standard Instruments

Last checked: Nov 20, 2026Latest source record: Dec 17, 2024 (this record)Source: ClinicalTrials.govMethods & limitations

Active, not recruiting

Status

Active, not recruiting

Enrollment

70

Actual

Start

Mar 3, 2014

Primary completion

Dec 2019

Study completion Dec 2024

Sponsor

Lead sponsor
Vastra Gotaland RegionGovernment (non-federal)
Sponsor type
Government (non-federal)
Collaborators
Zimmer Biomet; Ingabritt och Arne Lundbergs Forskningsstiftelse
First posted
Dec 6, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Single (outcomes assessor)
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 40 years, up to 75 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The goal of this randomized study is to see if using patient-specific instruments (PSI) during total knee replacement surgery improves outcomes compared to standard instruments. The study focuses on adults with knee osteoarthritis who need knee replacement surgery. Specifically, it aims to answer the following questions: Does using PSI improve knee function and stability as experienced by the patient? Does PSI lead to more normal knee motion during bending and straightening? Does PSI result in at least as good tibial (shin bone) component fixation as standard instruments? Is PSI more cost-effective than standard instruments? Researchers will compare PSI with standard instruments in 70 patients. Half will receive knee replacement surgery using PSI, and the other half with standard instruments. Patients will be randomly assigned to each group. Participants will: Undergo knee replacement surgery with either PSI or standard instruments. Have a series of follow-ups, including assessments of knee function, satisfaction, and alignment of the knee implant, conducted before surgery and at 3 months, 1 year, 2 years, and 5 years after surgery. The study will include patients aged 40-75 with primary osteoarthritis, a body mass index (BMI) below 35, and no other major medical conditions that could impact surgery. Patients will also need to be willing to undergo necessary imaging, such as magnetic resonance imageing (MRI) scans and standing X-rays. Outcomes will be measured using various assessment tools, including the Oxford Knee Score, Knee Society Score, and a patient satisfaction survey. Researchers will also record surgery details, such as operating time, blood loss, and knee implant size. Imaging methods, including MRI, computed tomgraphy (CT) scans, and specialized X-rays, will be used to evaluate knee alignment and stability over time. The results of this study are expected to provide insights into whether patient-specific instruments offer clinical or economic advantages over traditional tools in knee replacement surgery.

Conditions

  • Primary Osteoarthritis Patients Scheduled for Total Knee Replacement Surgery
  • Osteoarthritis (OA) of the Knee

Interventions

  • Patient specific instrumentation (PSI)Device

    Cutting guides that are manufactured using advanced imaging and modelling techniques to create instruments that align more closely with the unique anatomy of each patient. Custom guides were created based on a preoperative MRI protocol (Zimmer Patient Specific Instrumentation for NexGen® Complete Knee Solution, Zimmer Biomet, Warsaw, Indiana, United States in collaboration with Materialise NV, Leuven, Belgium) to optimize the placement of the components without the need for intramedullary alignment.

  • Conventional instrumentsDevice

    Instruments specific to the implant that are used to guide bone cutting in reference to the intramedullary canal or using an extramedullary jig.

  • Cemented Total Knee ArthroplastyProcedure

    A cemented TKA (NexGen® Complete Knee Solution, Zimmer Biomet, Warsaw, Indiana, United States) is used in all cases with a cruciate retaining (CR) or posterior stabilized (LPS) prosthesis as determined by the surgeon.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Oxford Knee Score (OKS)Time frame: Prior to and 2 years post surgery

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Sahlgrenska University Hospital

    Mölndal, Västra Götalandsregionen, Sweden

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.