Clinical Study to Evaluate the Impact of the Accu-Chek SmartGuide CGM Solution on the Mean Change in Time in Range Compared With Self-Monitoring of Blood Glucose in Participants With Type 1 and Type 2 Diabetes Mellitus

Clinical Study to Evaluate the Impact of the Accu-Chek SmartGuide CGM Solution on the Mean Change in Time in Range of 70 - 180 mg/dl Compared to SMBG

Last checked: Nov 19, 2026Latest source record: Oct 26, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

RecruitingPivotal-lookingRandomized with 270 participants. This is a heuristic, not a regulatory label.

Status

Recruiting

Enrollment

270

Planned (sponsor's estimate)

Start

Apr 14, 2025

Primary completion

Nov 15, 2026

Study completion May 30, 2027

Sponsor

Lead sponsor
Hoffmann-La RocheNot on our public-company list
Sponsor type
Industry
Collaborators
Roche Diabetes Care
First posted
Nov 26, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This is an open label, two-arm, randomized multi-center clinical device study in adult subjects with Type 1 diabetes (T1D) or insulin-dependent Type 2 diabetes (T2D) on a multiple daily injection (MDI) regime. The goal of the study is to investigate the impact of the Accu-Chek SmartGuide CGM solution on the change in overall time in range (TIR) of blood glucose concentrations of 70-180 mg/dl compared with that using self-monitoring of blood glucose (SMBG).

Conditions

  • Type 1 Diabetes Mellitus
  • Type 2 Diabetes Mellitus

Interventions

  • Accu-Chek SmartGuide CGM SolutionDevice

    The Accu-Chek SmartGuide CGM solution is used for real-time continuous glucose monitoring (CGM) in the interstitial fluid. It consists of the Accu-Chek SmartGuide device and two smartphone applications (apps): the Accu-Chek SmartGuide app and the Accu-Chek SmartGuide Predict app. The Accu-Chek SmartGuide device contains a CGM sensor pre-assembled in a sensor applicator. It has connectivity to the smartphone that is running the Accu-Chek apps. The Accu-Chek SmartGuide app is the primary display of the real-time glucose values. The Accu-Chek SmartGuide Predict app is an information management tool that further visualizes and analyzes diabetes data from the Accu-Chek SmartGuide device.

  • Accu-Chek SmartGuide Sensor and Blinded AppsDevice

    The participants in the SMBG control group will wear a SmartGuide sensor with blinded SmartGuide apps intermittently, i.e., during the assessment periods. It is not possible to read out the glucose data from the blinded app, hence neither the SmartGuide app nor the SmartGuide Predict functionalities can be accessed by the participants in this group.

  • SMBG DeviceDevice

    With the SmartGuide apps in blinded mode, participants in the SMBG control group will continue using their own SMBG device or they may use the Accu-Chek Instant meter that will be provided for calibration of the SmartGuide device.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change in the Percentage of Time in Range of a Blood Glucose Concentration of 70 to 180 mg/dL from the Baseline Period to Assessment Period ATime frame: Baseline Period (Weeks 1 and 2) and Assessment Period A (Weeks 5 and 6)

Locations

20 sites in 2 countries. Site status is shown where the registry gives one.

  • Centrum Badań Klinicznych PI-House sp. z o.o.

    Gdansk, Poland · Recruiting

  • Diabetes Technology Center, Jagiellonian University Medical College

    Krakow, Poland · Recruiting

  • NZOZ Neuromed

    Kraśnik, Poland · Recruiting

17 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.