All In MedTech

Device Trial Radar · NCT06680154

Induction and Stabilization of Gamma Oscillations With 40 Hz External Brain Stimulation

Gamma Oscillations and Working Memory Following Combined 40Hz tACS and iTBS

Last checked: Nov 19, 2026Latest source record: Mar 18, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

30

Actual

Start

Jul 13, 2021

Primary completion

Nov 30, 2023

Study completion Nov 30, 2023

Sponsor

Lead sponsor
The National Brain Mapping Laboratory (NBML)Academic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Leibniz Research Centre for Working Environment and Human Factors
First posted
Nov 8, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Single group
Masking
Single (participant)
Primary purpose
Basic science
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 60 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

The goal of the present studies is to develop and validate novel stimulation protocols for the entrainment of gamma oscillations, which are associated with many cognitive functions and critically involved in cognitive impairment such as Alzheimer's disease. In this proposal, combination of repetitive transcranial magnetic stimulation (rTMS) and transcranial alternating current stimulation (tACS), which has been shown effective for the induction, and stabilisation of alpha and theta frequencies in our forgoing studies, will be adopted to the gamma frequency range and applied on prefrontal regions as well as model-based cortical areas to enhance and stabilize gamma oscillations, thereby facilitating cognition

Conditions

  • Alzheimer Disease
  • Working Memory
  • EEG Brain Oscillations

Interventions

  • Transcranial alternating current stimulationDevice

    Transcranial alternating current was delivered utilizing a Starstim 8-channel constant current, battery-powered electric stimulator (Neuroelectrics, Barcelona, Spain). Circular carbon rubber electrodes (2cm radius, 12,57 cm2) were used throughout the stimulation. Before placing the electrodes on the head, the subject's hair was moved to the side

  • Theta burst stimulationDevice

    the intermittent theta burst stimulation (iTBS) which is regarded as safe for high-frequency neuromodulation. Compared to classical rTMS, where pulses are applied repeatedly at a fixed frequency, iTBS consists of bursts of pulse triplets. In the classical protocol, the bursts are applied for two seconds in 5Hz intervals followed by an eight-second break, before the next bursts are applied. This pattern is repeated for 190 seconds resulting in 600 pulses per protocol.

  • Sham (No Treatment)Device

    In the case of sham TMS, two different sham coils (double 70mm pCool-SHAM coil, Mag\&More GmbH, Munich, Germany) will produce audible clicks at the decibel intensity corresponding to an active coil without the induction of an electromagnetic pulse. Sham tACS will be applied by only ramping the current for 15 seconds up and 15 seconds down at the beginning and end of the stimulation respectively.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Working Memory behavioral performanceTime frame: During procedure (20 minutes)
  2. electroencephalogram (EEG) oscillatory powerTime frame: up to 2 hours after the intervention
  3. electroencephalogram (EEG) functional connectivityTime frame: up to 2 hours after the intervention

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Leibniz-Institut für Arbeitsforschung

    Dortmund, North Rhine-Westphalia, Germany

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.