Comparative Analysis of the Visual Performance and Patient Satisfaction After Cataract Surgery With Implantation of a Medicontur Monofocal (877PAY) or a Medicontur Extended Depth of Focus (877PEY) IOL

Last checked: Nov 20, 2026Latest source record: Oct 15, 2024 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

64

Actual

Start

Dec 2, 2020

Primary completion

Nov 21, 2023

Study completion Jan 24, 2024

Sponsor

Lead sponsor
Medicontur Medical Engineering LtdNot on our public-company list
Sponsor type
Industry
First posted
Oct 15, 2024

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
All sexes, from 18 years

Summary

As written by the sponsor on the registry.

The purpose of this multi-center, prospective, randomized, comparative clinical investigation was to evaluate and compare the visual performance at far, intermediate and near distances, the presence of photopic phenomena and patient satisfaction after cataract surgery in patients implanted binocularly with a Medicontur monofocal (877PAY) or a Medicontur extended depth of focus (877PEY) IOL models. The visit schedule included a total of 6 visits, in addition to the IOL implantation surgery, with the listed follow-up timeline: * screening and baseline assessments * day 0 (IOL implantation surgery) * day 1 * month 1 * month 3 * month 6 * month 12

Conditions

  • Cataract
  • Presbyopia
  • Ametropia

Interventions

  • VFQ- 25 (Visual Function Questionnaire)Behavioral

    VFQ-25 questionnaire was used to evaluate patient satisfaction at the M3 and M12 visits.

  • Optical BiometryDiagnostic test

    Axial length, anterior chamber depth and corneal keratometric values K1-K2. All these parameters were measured at the screening visit and at the month 3 follow-up visit, using the ARGOS® Biometer or the ANTERION® Cataract App

  • Slit lamps / Fundoscopy / BiomicroscopyDiagnostic test

    The fundus and other ocular structures, such as the cornea, anterior chamber, iris, pupil, crystalline lens / IOL alignment, corpus ciliare and choroid were examined at screening visit, on the day of the surgery, and at the follow up visits D1, M1, M3, M6, and M12, using the slit lamp binocular indirect ophthalmoscopy.

  • UDVADiagnostic test

    Monocular and binocular Uncorrected Distance Visual Acuity (UDVA) was evaluated at all visits (preoperative, D1, M1, M3, M6 and M12), using the ETDRS chart.

  • CDVADiagnostic test

    Monocular and binocular Corrected Distance Visual Acuity (UDVA) was evaluated at all visits (preoperative, D1, M1, M3, M6 and M12), using the ETDRS chart.

  • UIVA / DCIVADiagnostic test

    Uncorrected and Distance Corrected Intermediate Visual acuity (UIVA / DCIVA) was evaluated postoperatively at M1, M3, M6 and M12, using an intermediate chart from 67 cm.

  • UNVA / DCNVADiagnostic test

    Uncorrected and Distance Corrected Near Visual acuity (UNVA / DCNVA) was evaluated postoperatively at M1, M3, M6 and M12, using a near chart from 40 cm.

  • Manifest RefractionDiagnostic test

    Manifest refraction was the monocular subjective refraction (Sph, Cyl, Axis) giving the best distance corrected visual acuity. It was measured at the screening visit and the follow-up visits Day 1, Month 1, Month 3, Month 6 and Month 12.

  • IOPDiagnostic test

    Intraocular pressure (IOP) was measured at all visits (preoperative, D1, M1, M3, M6 and M12), using a non-contact tonometer.

  • VADCDiagnostic test

    Visual Acuity Defocus Curve (VADC) was taken monocularly at M3, monocularly and binocularly at M6 and binocularly at M12, using the Multifocal Lens analyzer - MLA application.

  • CSDCDiagnostic test

    Contrast Sinsitivity Defocus Curve (CSDC) was taken under photopic conditions at M6 and M12, using the Multifocal Lens Analyzer - MLA application

  • CSV-1000Diagnostic test

    Contrast Sensitivity was measured using the CSV-1000 with distance correction in place at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd). Measurements were taken under four different light conditions: * Photopic (M3 monocular and binocular, M6 binocular and M12 monocular) * Mesopic (M6 binocular) * Photopic with backlight (M6 binocular) * Mesopic with backlight (M6 binocular)

  • Tear film stabilityDiagnostic test

    Tear film stability was assessed at screening visit and at follow-up visits M1, M3, M6, and M12 using the non-invasive Tear break Up Time (TBUT) with fluorescein dye.

  • IOL implantationDevice

    The investigational device (877PEY) and the comparator (877PAY) intraocular lens models were implanted, using sutureless, small-incision phacoemulsification surgery.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. DCIVATime frame: measured at month 1, month 3, month 6 and month 12

Locations

3 sites in 1 country. Site status is shown where the registry gives one.

  • Borsod-Abaúj-Zemplén Vármegyei Központi Kórház és Egyetemi Oktatókórház

    Miskolc, BAZ Vármegye, Hungary

  • Győr-Moson-Sopron Vármegyei Petz Aladár Egyetemi Oktató Kórház

    Győr, Győr-Moson-Sopron Vármegye, Hungary

  • Retinaszerviz Kft.

    Veszprém, Veszprém Vármegye, Hungary

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.