Device Trial Radar · NCT06626490
Prospective Follow-up of the Prevision Hip Stem With Comparison of Different Implant Variants
Last checked: Nov 20, 2026Latest source record: Nov 9, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
120
Planned (sponsor's estimate)
Start
Apr 7, 2026
Primary completion
Mar 2033
Study completion Mar 2034
Sponsor
- Lead sponsor
- Aesculap AGNot on our public-company list
- Sponsor type
- Industry
- First posted
- Oct 3, 2024
Design
- Study type
- Observational
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The study design is confirmative for non-inferiority of the functional outcome of the implants and is intended to examine the safety and performance of the Prevision hip stem. The study is an observational post-market clinical follow-up study, and the study sites chose the stem variant depending on their own routine and indication.
Conditions
- Revision Total Hip Arthroplasty
- Periprosthetic Fracture of Hip
Interventions
Prevision Revision hip endoprosthesis stem implantationDevice
The Prevision hip endoprosthetic stem is a femoral part of a hip joint endoprosthesis. The system provides cementless and cemented variants. Prevision hip stems are modular with a short proximal and longer distal component, or monobloc hip stems. Modular components are coupled via a Prevision specific conical connection with a torque wrench and a tension nut to apply a predefined torsional moment on the connection. The distal component of modular Prevision stems can be combined with locking screws for additional bone fixation. Both types, the monobloc and the modular, provide a 12/14 taper that serves as a connection for metal or ceramic prosthesis heads. Prevision hip stems are combined at the acetabulum with a cementless or cemented acetabular cup.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Functional outcome of the hip revision surgeryTime frame: Pre OP, Follow Up (FU) 3 months, FU (1 year), FU (2 years), FU (5 years)
Locations
2 sites in 2 countries. Site status is shown where the registry gives one.
Orthopädische Kliniken im Annastift, MHH, Anna-von-Borries-Str. 1-7
Hanover, Germany · Recruiting
Hinchingbrooke Hospital
Huntingdon, Cambridgeshire, United Kingdom · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.