Device Trial Radar · NCT06567262
Compare CAD/CAM Metallic RPD to Conventional Metallic RPD in Terms of Oral Health Related Quality of Life
Last checked: Nov 19, 2026Latest source record: Aug 26, 2024 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Status unknown
Enrollment
19
Planned (sponsor's estimate)
Start
Oct 2024
Primary completion
Dec 2024
Study completion Mar 2025
Sponsor
- Lead sponsor
- Cairo UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Aug 22, 2024
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- Quadruple (participant, care provider, investigator, outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
Patients will be randomised to receive CAD/CAM metallic removable partial denture (RPD) followed by Conventional metallic RPD (Group A), or the opposite sequence (Group B), with a 3-month wear duration for each denture and washout period for one week. Patients will be recalled at base line and 3 months following prosthetic insertion to evaluate Oral health related quality of life. It is hypothesized that removable partial dentures with CAD/CAM metallic RPD frameworks would improve Oral health related quality of life than those with Conventional metallic RPD frameworks.
Conditions
- Partial Edentulism Class 3
Interventions
CAD/CAM metallic removable partial dentureDevice
Make digital scans using an intraoral scanning device. Scan the maxillary (antagonistic scan) and mandibular (pre-preparation scan) arches, as well as an initial digital record of the inter-occlusal relation (occlusal scan). Analyse the digital cast using CAD software. Primary electronic surveying will be carried out to ensure if the tooth preparations will be needed. Make a definitive intraoral scan only of the prepared teeth and record the maxillary-mandibular relationship. The virtual cast is digitally surveyed and the design of the framework is done using computer software. The wax pattern 3D framework information will be converted into a standard tessellation language (STL) file and transfer to a rapid prototyping (RP) system to be printed and finally cast using the conventional technique to produce RPD framework.
Conventional metallic removable partial dentureDevice
Primary impressions will be taken, the impressions will be poured to construct a study casts. Maxillary Face-bow record and diagnostic bite will be taken. The study casts will be mounted on semi adjustable articulator to check inter-arch space. Surveying of the study cast will be done. Required mouth preparation will be carried out then secondary impression will be taken using special tray. Secondary impression will be poured to obtain master cast which will be surveyed to confirm proper mouth preparation, blocked out and then wax pattern will be designed and constructed. A metallic framework will be obtained using the conventional lost wax technique and casting. Intraoral try in of the framework will be done followed by bite registration record. The next step will be teeth setting and try in. Heat cured acrylic resin denture base will be processed, finished and polished conventionally.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Oral health related quality of lifeTime frame: 3 months
Locations
No sites are listed on the registry yet.
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.