All In MedTech

Device Trial Radar · NCT06513299

Effectiveness of Low Volume and Low Pressure in Severe Hypoxemic Patients

Assessing the Effectiveness of Low Tidal Volume and Low Driving Pressure in Mechanically Ventilated Severe Hypoxemic Patients: a Multicenter Emulated Target Trial

Last checked: Nov 19, 2026Latest source record: Dec 27, 2024 (this record)Source: ClinicalTrials.govMethods & limitations

Active, not recruiting

Status

Active, not recruiting

Enrollment

4,300

Planned (sponsor's estimate)

Start

Dec 24, 2024

Primary completion

Aug 1, 2025

Study completion Dec 31, 2025

Sponsor

Sponsor type
Academic, hospital or other
Collaborators
Istituto Di Ricerche Farmacologiche Mario Negri; University of Bari Aldo Moro
First posted
Jul 22, 2024

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The present study set up to answer two questions: (a) "how low tidal volume must be to provide protective ventilatory settings able to minimize the risk of death due to Ventilator-Induced Lung Injury (VILI)?"; (b) "if protection from VILI is better achieved by targeting the driving pressure instead of the tidal volume, what is the optimal target for the driving pressure?". Solving these questions is pivotal for clinicians to personalized and precise mechanical ventilation practices to reduce the risk of VILI and avoid unnecessary risks associated to protective ventilatory settings. Two multicenter emulated target trials will be performed using data collected with the Electronic Health Record MargheritaTre, to investigate the effect of low tidal volumes (6.0 to 8.0 ml/kg PBW vs 8.0 to 10.0 ml/kg PBW) and low driving pressures (7.0-12.0 cmH2O vs 12.0-18.0 cmH2O), respectively. Data will be used to obtain the dose-response curve of lower VT and lower ∆P in mechanically ventilated patients with acute severe hypoxemia.

Conditions

  • Hypoxemia
  • Ards

Interventions

  • low tidal volumeDevice

    Patients ventilated with assist/control modes of mechanical ventilation with tidal volume between 6.0 ml/kg PBW and 8.0 ml/kg PBW with PPLAT ≤ 30 cmH2O, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

  • high tidal volumeDevice

    Patients ventilated with assist/control modes of mechanical ventilation with tidal volume between 8.0 ml/Kg PBW and 10.0 ml/kg PBW with PPLAT ≤ 30 cmH2O, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

  • low driving pressureDevice

    Patients ventilated with assist/control modes of mechanical ventilation with driving pressure between 7.0 cmH2O and 12.0 cmH2O with VT ≤ 10 ml/kg PBW, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

  • high driving pressureDevice

    Patients ventilated with assist/control modes of mechanical ventilation with driving pressure between 12.0 cmH2O and 18.0 cmH2O with VT ≤ 10 ml/kg PBW, until weaning criteria are met: P/F ratio \> 250 mmHg; PEEP ≤ 8 cmH2O and lower than the previous day; FiO2 \< 0.5 and lower than the previous day; systolic arterial pressure ≥ 85 mmHg.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. ICU all-cause mortalityTime frame: 14 days from assignment to intervention arm

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Mario Negri Institute for Pharmacological Research IRCCS

    Ranica, BG, Italy

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.