All In MedTech

Device Trial Radar · NCT06468189

Clinical and Neurophysiological Effects of tDCS to Visual and Motor Cortex in Migraine

Clinical and Neurophysiological Effects of Simultaneous Application of tDCS to Visual and Motor Cortex in Migraine; Double Blind Randomized Controlled Study

Last checked: Nov 19, 2026Latest source record: Nov 5, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Active, not recruiting

Status

Active, not recruiting

Enrollment

80

Planned (sponsor's estimate)

Start

Mar 1, 2024

Primary completion

Nov 2026

Study completion Nov 2027

Sponsor

Lead sponsor
Istanbul Medipol University HospitalAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Alanya Alaaddin Keykubat University; Saglik Bilimleri Universitesi
First posted
Jun 21, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Double (participant, investigator)
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 55 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

tDCS can be offered as an alternative to migraine patients who have frequent and severe attacks and who are resistant to or unresponsive to preventive drug therapy. Additionally, this technique may also be an option for patients who refuse or have contraindications to taking anti-migraine medications. A decrease in headache severity and frequency is expected with this neuromodulation applied to migraine patients with frequent attacks. Based on this hypothesis; This tested whether simultaneous modulation of motor (M1, left) and visual cortex (O1 or O2, ipsilateral) with tDCS applied for 3 consecutive days is an effective treatment for migraine patients for the following specific purposes . No significant undesirable effects are expected, except for possible side effects that are simple and do not require medical intervention, such as tingling or itching in the area where the electrodes are attached, moderate fatigue, mild headache, nausea at a rate of less than 3%, and insomnia at a rate of less than 1%. . The research will be conducted within the framework of ethical principles and in accordance with the good clinical practice protocol. A) The primary purpose of this study is to determine whether transcranial direct current stimulation applied simultaneously to the motor and visual cortex in migraine patients provides a significant reduction in pain due to migraine attacks compared to sham tDCS. Additionally, to evaluate the effects of this treatment, They will be measured changes in the number of migraine attacks, abortive medication intake (e.g., opioids, triptans), as well as overall improvement in cognitive status and quality of life. In addition, electrophysiological EEG evaluations, before and after treatment, and the results of these measurements, as a potential biomarker in migraine, will be compared in the active and sham groups. B) It is aimed to determine whether the clinical effects of tDCS are long-lasting. Therefore, It will compared whether there is a difference in improvement of migraine-related pain between active and sham tDCS at pre-treatment (baseline) assessments as well as at 1, 2, and 3 months after treatment. C) Finally, it will be examined whether tDCS treatment applied for 3 consecutive days in migraine patients is safe. Safety will be evaluated through neuropsychological testing and adverse event reporting.

Conditions

  • Migraine

Interventions

  • transcranial direct stimulationDevice

    Mars-01(Marslab, Turkey) transcranial direct current stimulation device works with a 9 volt battery and consists of two 5x5 (25 cm2) electrodes (anode and cathode). 3 consecutive sessions (days), cathodal to occipital cortex (O1 or O2, ipsilateral); Anodal application will be made to M1 (left). Active stimulation is 2mA tDCS with a 0 to 30 second acceleration period of 20 minutes per session. Placebo stimulation will be applied according to the device's own sham software protocol. Accordingly, the current consists of 30 seconds of increase from 0 to 2mA(milliamp), 10 seconds of stimulation, 30 seconds of decrease to 0 and 20 minutes of current-free application.

  • Sham treatmentDevice

    The same device used for stimulation will be used, but no stimulation will be given.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change in headache diary variablesTime frame: Baseline (Before Treatment) / 1 month and 3 months after treatment

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • İstanbul Medipol University

    Istanbul, Beykoz, Turkey (Türkiye)

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.