All In MedTech

Device Trial Radar · NCT06451068

Peripheral Retina Robotically Aligned OCT Study

Assistive Robotically Aligning Optical Coherence Tomography of the Retinal Periphery

Last checked: Nov 20, 2026Latest source record: Apr 13, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Withdrawn

Status

Withdrawn

Enrollment

0

Actual

Start

Jan 2026

Primary completion

Mar 31, 2026

Study completion Mar 31, 2026

Sponsor

Lead sponsor
Duke UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
National Institutes of Health (NIH); National Eye Institute (NEI)
First posted
Jun 10, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Non randomized
Model
Parallel
Masking
None
Primary purpose
Other
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

Optical coherence tomography (OCT) is a 3D imaging technology that has seen wide adoption within ophthalmology. However, optical access to the retinal periphery remains a challenge for conventional OCT systems. The study team plans to innovate peripheral retinal OCT imaging technology by first developing the first robotic OCT system capable of autonomously assisting the operator during imaging of the human peripheral retina using 3D active tracking and compensation and then by developing of the first OCT system designed for treatment of the retinal periphery.

Conditions

  • Retinal Disease

Interventions

  • Peripheral retina robotically aligned optical coherence tomography (OCT) systemDevice

    To visualize the full 360° of the retinal periphery (from equator to the more anterior ora serrata), investigators developed and redesigned a conical mirror contact lens and our non-contact robotically aligning platform to deliver OCT to the peripheral retina. The peripheral retina robotically aligned OCT (PR-RAOCT) system is built around a 6-axis cooperative robot (UR5e, Universal Robots), using our previously developed RAOCT control software.

  • Likert ScalesOther

    Survey evaluating relative comfort with each type of peripheral exam (scleral depression vs. PR-RAOCT). Participants will rate 3 items on a 1 (non) to 5 (maximum) Likert scale: overall discomfort, physical pain, and photophobia for each exam.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Presence of peripheral retinal break/s - Optical Coherence Tomography (OCT)Time frame: Single imaging session (day 1)
  2. Presence of peripheral retinal break/s - clinical examTime frame: Single imaging session (day 1)

Locations

No sites are listed on the registry yet.

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.