All In MedTech

Device Trial Radar · NCT06423378

Bio-Integrative, Fiber-Reinforced Kneebar for Treating Subchondral Insufficiency of the Knee

Last checked: Nov 19, 2026Latest source record: May 29, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Enrolling by invitation

Status

Enrolling by invitation

Enrollment

10

Planned (sponsor's estimate)

Start

Mar 5, 2025

Primary completion

Mar 5, 2027

Study completion Dec 5, 2027

Sponsor

Lead sponsor
Vanderbilt University Medical CenterAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
May 21, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Phase 2
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 18 years, up to 75 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The OSSIOfiber® Trimmable Fixation Nails are indicated for maintenance of alignment and fixation of bone fractures, osteotomies, arthrodesis and bone grafts in the presence of appropriate additional immobilization (e.g., rigid fixation implants, cast, brace). Our hypothesis is that the use of OSSIOfiber® Trimmable Fixation Nails for treating subchondral insufficiency of the knee will result in improvement of patient-reported outcomes and imaging findings. The primary objective of this study is to evaluate the effectiveness of implanting bio-integrative OSSIOfiber® Trimmable Fixation Nails, organized in a bi-cortical rafter formation within the tibia or femur for the management of subchondral insufficiency. The OSSIOfiber® Trimmable Fixation Nails used in this study will be considered on-label.

Conditions

  • Subchondral Insufficiency Fracture

Interventions

  • OSSIOfiber® Trimmable Fixation NailsDevice

    Subjects will be treated with cannulated nails before or after arthroscopic management of their concomitant pathology at the discretion of the investigator. Technique described below. Following nail placement, tissue layers will be closed in standard fashion. 1. Preop MRI views used to estimate the proper depth \& location of nail placement on the femur and/or tibia 2. Exposure is gained to medial tibia 3. 1.4 mm K-Wire is placed through medial tibia parallel to the articular joint surface \~ 1 cm distal to the articular joint line 4. A depth gauge is placed over K-Wire to determine required length of cannulated nail 5. A 4.0 mm cannulated drill bit used over K-Wire to prepare the pilot hole 6. Tamp is used to insert pre-trimmed 4.0 mm cannulated nail into the pilot hole and K-Wire is subsequently removed 7. Intraop fluoroscopy can confirm adequate nail placement prior to removing K-wire 8. Repeat steps for additional nails

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Knee injury and Osteoarthritis Outcome Score (KOOS)Time frame: 3 months post-operatively
  2. Knee injury and Osteoarthritis Outcome Scale Score (KOOS)Time frame: 6 months post-operatively

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Vanderbilt University Medical Center

    Nashville, Tennessee

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.