Device Trial Radar · NCT06377007
Refractive Outcomes and Ocular Biometry of Two Swept-Source Optical Coherence Tomography-Based Biometers With Segmental or Equivalent Refractive Indices (ORION)
Last checked: Nov 19, 2026Latest source record: May 15, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
144
Actual
Start
May 1, 2024
Primary completion
Jan 31, 2025
Study completion Jan 31, 2025
Sponsor
- Lead sponsor
- Walailak UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Apr 22, 2024
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Double (participant, outcomes assessor)
- Primary purpose
- Other
- FDA-regulated device
- No
- Who can join
- All sexes, from 40 years, up to 90 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This prospective, single-centre, randomized, parallel-group comparative clinical study evaluated the refractive prediction accuracy of two swept-source optical coherence tomography (SS-OCT) biometers in a Thai cataract surgery cohort. The ARGOS biometer applies segmental refractive indices to individual ocular segments, whereas the IOLMaster 700 applies an equivalent refractive index to the whole eye. Each device is conventionally paired with a different keratometry-formula combination: ARGOS with the standard Barrett Universal II (Barrett UII K), and IOLMaster 700 with the Barrett Universal II using total keratometry (Barrett UII TK). The study compared these two device-formula pairings as they are used in routine clinical practice. Both biometers were performed on every eye on the same day, enabling a within-subject paired comparison of biometric agreement and refractive prediction error at one month after phacoemulsification cataract surgery with implantation of a TECNIS Monofocal one-piece IOL (model GCB00V)
Conditions
- Cataract
Interventions
IOLMaster 700 (Carl Zeiss Meditec AG)Device
Preoperative biometric measurement using the IOLMaster 700 (software version 1.90.10). IOL power was calculated using the Barrett Universal II TK formula and used for power selection in this arm.
ARGOS (Movu/Santec; distributed by Alcon)Device
Preoperative biometric measurement using the ARGOS (software version A2.4). IOL power was calculated using the Barrett Universal II K formula and used for power selection in this arm.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Mean absolute prediction errorTime frame: 4 weeks
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Walailak University
Nakhon Si Thammarat, Changwat Nakhon Si Thammarat, Thailand
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.