Device Trial Radar · NCT06360393
Inhaler Adherence and Inhalation Technique Assessed by a Smart Spacer in Patients With Severe Asthma on Biologics
Last checked: Nov 19, 2026Latest source record: Nov 16, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
110
Planned (sponsor's estimate)
Start
May 1, 2024
Primary completion
Dec 2026
Study completion Dec 2026
Sponsor
- Lead sponsor
- University Medical Center GroningenAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- Collaborators
- Trudell Medical International
- First posted
- Apr 11, 2024
Design
- Study type
- Observational
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Severe refractory asthma affects about 3.5% of asthma patients, often necessitating biologic therapy in addition to standard treatment. However, little is understood about maintenance and reliever inhalation medication adherence in these cases which might impact overall biologic response. Objectively monitoring inhalation medication adherence remains a significant challenge. The Smart AeroChamber® device, capable of measuring adherence and inhalation technique, is untested in severe asthma patients on biologics, presenting a potentially cost-effective solution to monitor adherence and better understand treatment response. This study aims to assess the feasibility of the Smart AeroChamber® device in severe asthma patients on biologic therapy, with objectives to: 1. Evaluate inhalation medication adherence patterns and inhaler technique, and comparing that adherence data with traditional measures e.g. the Test of Adherence to Inhalers (TAI), and an inhalation technique checklist. 2. Investigate the association between inhaled medication adherence and clinical outcomes such as exacerbations, short-acting beta-agonists (SABA) use, oral corticosteroids use (OCS), Fractional Exhaled Nitric Oxide (FeNO), blood eosinophil count, and Asthma Control Questionnaire (ACQ) scores. 3. Assess patient and healthcare provider satisfaction and usability of the Smart AeroChamber® device. The study design is prospective and observational, with a sample size of 110 adult patients diagnosed with severe asthma using biologic therapy. Participants will be followed for 12 months, during which they will receive Smart AeroChamber® devices. These devices will measure medication adherence and inhaler technique, and undergo assessments of clinical outcomes at regular intervals. Usability and satisfaction will also be evaluated using the Systems Usability Scale (SUS) in patients and healthcare professionals. The study will be conducted across five severe asthma clinics in the Netherlands. Data analysis will involve comparing the inhalation medication adherence data with traditional measures for adherence and inhalation technique, assessing clinical outcomes, and evaluating usability and satisfaction. The findings from this study will provide insights into the feasibility and effectiveness of using digital devices like the Smart AeroChamber® to support medication adherence and possibly improve outcomes in patients with severe asthma on biologic therapy.
Conditions
- Asthma
Interventions
Smart spacerDevice
Participants' inhalation medication adherence and inhalation technique will be monitored using a smart spacer. Their usual medication regime will be continued and they will not receive information about their adherence or inhalation technique measured by the spacer during the follow-up year (except for any interventions that will be done in standard care).
Primary outcomes
What the sponsor says the trial is designed to measure.
- Comparative analysis of smart spacer medication adherence and inhaler technique against Test of Adherence to Inhalers (TAI-12)Time frame: TAI is measured at baseline and 12 months
- Comparison of smart spacer medication adherence patterns (adherence and inhaler technique) with inhaler checklist examined by pulmonologist or pulmonary nurseTime frame: Inhaler checklist is assessed at baseline and 12 months
Locations
5 sites in 1 country. Site status is shown where the registry gives one.
Isala
Zwolle, Overijssel, Netherlands · Recruiting
Medisch Centrum Leeuwarden
Leeuwarden, Provincie Friesland, Netherlands · Recruiting
University Medical Center Groningen
Groningen, Provincie Groningen, Netherlands · Recruiting
2 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.