All In MedTech

Device Trial Radar · NCT06331052

3-D Tractography FUS Ablation for Essential Tremor

3-D Tractography Focused Ultrasound Ablation for Essential Tremor

Last checked: Nov 19, 2026Latest source record: Sep 8, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

24

Planned (sponsor's estimate)

Start

Feb 28, 2024

Primary completion

Feb 28, 2028

Study completion Feb 28, 2028

Sponsor

Lead sponsor
University of North Carolina, Chapel HillAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
University of Pittsburgh; National Institute of Neurological Disorders and Stroke (NINDS); University of Missouri-Columbia
First posted
Mar 26, 2024

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 22 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The investigators propose to advance Vim-FUSA (Ventral Intermediate Nucleus - Focused Ultrasound Ablation) with the support of 3-D tractography, a neuroimaging technique to visually represent nerve tracts within the brain. The investigators hypothesize that 3-D tractography Vim-FUSA will improve the Vim ablation compared to standard Vim-FUSA and prove safe and feasible in the clinical setting. The investigators also hypothesize that intraoperative magnetic resonance (i-MR) monitoring will differentiate ablated tissue from immediate perilesional edema and accurately predict the Vim-FUSA clinical outcomes.

Conditions

  • Essential Tremor

Interventions

  • MR-guided Focused Ultrasound AblationDevice

    3-D tractography Vim-FUSA -D tractography Vim-FUSA will be carried out as follows: (a) head shaving and placement of the stereotactic frame (Integra radionics frame, Integra Lifesciences, NJ, USA) secured to the skull with transcutaneous screws; (b) positioning on the procedure table and placement of the ultrasound transducer; (c) acquisition of conventional magnetic resonance (MR) imaging and co-registration with the CT head and 3-D tractography imaging acquired pre-surgically; (d) exploration of the target area with subtherapeutic sonications; (e) intraoperative monitoring with clinical testing of tremor and side effects with a standardized protocol. (f) Therapeutic sonications in the target area to deliver definitive ablation followed by clinical testing of tremor and side effects with a standardized protocol as described in section (e).

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Number of Participants without Side EffectsTime frame: during the surgical procedure
  2. Absolute Change in TremorTime frame: Baseline, Month 3
  3. Relative Change in TremorTime frame: Baseline, Month 3

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • University of North Carolina at Chapel Hill

    Chapel Hill, North Carolina · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.