Smartphone Twelve-Lead ECG Utility In ST-Elevation Myocardial Infarction II
Last checked: Nov 19, 2026Latest source record: Apr 9, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
1,000
Planned (sponsor's estimate)
Start
Mar 12, 2024
Primary completion
Dec 2026
Study completion Mar 2027
Sponsor
- Lead sponsor
- AliveCorNot on our public-company list
- Sponsor type
- Industry
- First posted
- Feb 22, 2024
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Diagnostic
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
AliveCor (www.alivecor.com) has developed several electrocardiogram (ECG) devices that interface with iOS and Android smartphones and tablets via various Kardia apps. The current Kardia family of devices can measure single lead and six limb-lead ECGs, depending on the device. KardiaMobile, KardiaMobile 6L, and KardiaMobile Card have FDA clearance for ECG rhythm recording. A modified single-lead Kardia smartphone 12-lead ECG was previously validated in the multicenter ST LEUIS study for the diagnosis of ST-Segment Elevation Myocardial Infarction (STEMI) and Non-ST-Elevation Myocardial Infarction (NSTEMI). Recently, AliveCor developed a new device: AliveCor (AC) 12-lead (12L) ECG System to record simultaneously 4 leads of ECG and then generate complete 12-lead ECGs. A previous protocol at the University of Oklahoma involved 200 subjects with early prototypes of the AC 12L device with the specific aim to validate that it accurately generated 12-lead ECGs as compared to simultaneously acquired FDA-cleared 12-lead ECGs. The prototype version of the AliveCor 12L ECG System simultaneously measured four channels of ECG (leads I, II, V2, V4), calculated the remaining limb leads as is standard for 12-lead ECGs (Leads III, aVR, aVL, aVF) and synthesized the remaining 4 precordial ECG leads (V1, V3, V5, V6). This protocol will serve to validate the production version of the system against standard 12-Lead ECGs for the diagnosis of STEMI and NSTEMI in patients admitted to the Emergency Department or directly to the Cardiac Cath Lab for the evaluation of chest pain. It is anticipated that the waveforms for each of the 12 leads from the AC 12L ECG System will be highly correlated with the corresponding leads from the comparator commercially available 12-lead ECG devices used at participating sites. The purpose of this study is to clinically validate that the four-channel AC 12L ECG device can enable the diagnosis of STEMI and NSTEMI in a non-inferior manner to existing 12-lead ECG devices.
Conditions
- Myocardial Infarction
- Ischemia
- Myocardial Ischemia
- Heart Diseases
- Cardiovascular Diseases
- Vascular Diseases
- Heart Attack
- Heart Failure
Interventions
AliveCor 12-lead ECGDevice
The primary objective of this study is to determine if the AliveCor 12-lead Smartphone ECG is an acceptable substitute for a standard 12-lead ECG in the identification of STEMI and NSTEMI.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Inter-rater variability for Standard 12-lead ECG readingsTime frame: 30 seconds
- Inter-rater variability for AC 12L ECG readingsTime frame: 30 seconds
- Number of standard 12-lead ECG readings requiring a consensus consultationTime frame: 30 seconds
8 more outcomes with a free account
Locations
4 sites in 2 countries. Site status is shown where the registry gives one.
Mayo Clinic
Rochester, Minnesota · Recruiting
Intermountain Health
Murray, Utah · Recruiting
Leeds General Infirmary
Leeds, England, United Kingdom · Not yet recruiting
1 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.