Device Trial Radar · NCT06212141
Comparison of Bulk-Fill Composite Resins in Class II Restorations
Last checked: Nov 19, 2026Latest source record: Nov 18, 2025 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Active, not recruiting
Enrollment
54
Actual
Start
Dec 12, 2022
Primary completion
Jun 15, 2024
Study completion Jun 15, 2026
Sponsor
- Lead sponsor
- Hacettepe UniversityAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jan 18, 2024
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Factorial
- Masking
- Single (outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years, up to 60 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
The goal of this clinical trial is to evaluate the clinical performance of Class II restorations of a thermoviscous nanohybrid materials , of a bulk-fill composite resin, and of conventional nanohyribrid bulk-fill composite resins . Class II restorations will be performed in patients using three different restorative materials.And restorations will be evaluated using modified US Public Health Service criteria Resorations will be photograped and restorations will be evaluated for 6,12 months.
Conditions
- Class II Dental Caries
Interventions
VisCalor Bulk,VOCO,GermanyDevice
It was placed class II restorations.Before applying it, a 37% orthophosphoric acid will be injected into the cavity for 30 sec. on the enamel and 15 sec. on the dentin. Then, cavity will be rinsed with pressurized air and water for 15 sec. and Futura Bond U adhesive agent will be applied to the enamel and dentin surfaces using a disposable applicator for 20 sec. Then light air pressure will be applied for 5 sec., and then polymerization will be carried out for 10 sec. using LED light. When it comes to the application of VisCalor , the VisCalor Gun , heating device will be used. A disposable composite capsule will be placed into the device, and it will be heated by selecting program 1 (65°C) for 30 sec. The material will remain hot for 2.5 min. The nozzle of the capsule on the gun will be directly applied to the deepest part of the cavity, ensuring that the material is placed from bottom to top without exceeding 4 mm. Polymerization will be carried out with LED for 10 sec.
Admira Fusion x-tra,VOCO,GermanyDevice
Admira Fusion x-tra composite resin was placed class II restorations. Before applying it an orthophosphoric acid with a concentration of 37% will be injected into the cavity for 30 sec. on the enamel and 15 sec. on the dentin. Then, cavity will be rinsed with pressurized air and water for 20 sec. And Futura Bond U adhesive agent will be applied to the enamel and dentin surfaces using a disposable applicator for 20 sec. Following the manufacturer's recommendations, light air pressure will be applied for 5 sec, and then polymerization will be carried out for 10 sec. using LED light with a power of 1200 mW/cm². Afterwards bulk-fill composite will be placed in the cavity, ensuring that each layer does not exceed 4 mm, and appropriate occlusal shaping will be performed. Polymerization will be carried out with LED light for 20 seconds.
Filtek One Bulk,3M,GermanyDevice
Filtek One Bulk composite resin was placed class II restorations. Before applyingthe material, a 37% orthophosphoric acid will be injected into the cavity for 30 sec. on the enamel and 15 sec. on the dentin, followed by rinsing the cavity with pressurized air and water for 20 sec.Then , adhesive agent will be applied to the enamel and dentin surfaces using a disposable applicator for 20 sec. Following the manufacturer's recommendations, light air pressure will be applied for 5 sec, and then polymerization will be carried out for 10 sec using LED light . Afterwards, bulk-fill composite will be placed in the cavity, ensuring that each layer does not exceed 4 mm, and appropriate occlusal shaping will be performed. Polymerization will be carried out with LED light at a power of 1200 mW/cm² for 10 sec from all directions, following the manufacturer's recommendations.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Marginal AdaptationTime frame: From baseline to 18 month
- Marginal StainingTime frame: From baseline to 18 month
- RetentionTime frame: From baseline to 18 month
2 more outcomes with a free account
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Hacettepe University
Ankara, Ankara, Turkey (Türkiye)
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.