Device Trial Radar · NCT06173648
Histopathological Evaluation of the Periodontal Ligament Subjected to Laser Ablation.
Last checked: Nov 20, 2026Latest source record: Feb 29, 2024 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
10
Actual
Start
Aug 1, 2023
Primary completion
Oct 23, 2023
Study completion Oct 31, 2023
Sponsor
- Lead sponsor
- CAO Group, Inc.Not on our public-company list
- Sponsor type
- Industry
- Collaborators
- São Paulo State University
- First posted
- Dec 18, 2023
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
Laser Ablation therapy (LA) using an 810nm diode laser and Indocyanine Green (ICG) solution, which efficiently absorbs laser energy and increases the effectiveness of tissue removal. Intracanal heating can potentially cause damage to structures outside the tooth root. The study was to observe possible changes in the periodontal ligament and cementum resulting outside the root using this treatment. Histological and morphological examination of extracted cementum, ligament, and collagen post-exposure showed no difference in these structures vs. non-treated controls.
Conditions
- Pulp Necroses
Interventions
Laser and ICG solution.Device
Intervention consists of addition of a combined laser absorption solution and infrared diode laser. The solution is introduced into the prepared pulp chamber and root canals, allowed to dwell for 1 minute, followed by exposure to the laser energy delivered via a fiber optic introduced into the root canal, and while activating the laser at 2.5 watts of optical output with a pulse duration of 100 msec and a pulse gap of 300 msec, the solution and residual structures in the root and pulp chamber are exposure over the course of 30 seconds, moving and relocating the fiber tip throughout the canals and chamber during that time. The laser is halted and a wait time of 30 seconds is applied. The laser fiber is then reintroduced and another 30 second exposure, repeating the same settings and technique.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Cell Count of Inflammatory Infiltrate Per Cross-Sectional Area at 400X MagnificationTime frame: 28 days after intervention.
2 more outcomes with a free account
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Unicesumar Clinic
Maringá, Paraná, Brazil
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.