Live Birth Rate After Sperm Selection Using ZyMōt Multi (850µL) Device for Intra Uterine Insemination
Last checked: Nov 20, 2026Latest source record: Jan 30, 2024 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
240
Planned (sponsor's estimate)
Start
Jan 10, 2024
Primary completion
Dec 2026
Study completion Dec 2027
Sponsor
- Lead sponsor
- Universitair Ziekenhuis BrusselAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Nov 22, 2023
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Quadruple (participant, care provider, investigator, outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years, up to 36 years
- Healthy volunteers
- Yes
Summary
As written by the sponsor on the registry.
This single centre interventional pilot randomized control study intends to compare two methods of sperm preparation for couples referred for Intra Uterine Insemination (IUI) procedure. Couples will be randomly allocated to one of the two sperm selection methods: Density Gradient Centrifugation (DGC, standard) or ZyMōt Multi (850µL) device (treatment) groups. The study will compare the live birth rate (number of live births per number of IUI procedures) between the treatment and standard groups.
Conditions
- Infertility
- Fertility Disorders
Interventions
ZyMōt Multi (850µL)Device
An amount of 850 µl untreated semen sample will be loaded into the inlet chamber with a help of a sterile insulin-type syringe. A volume of 750 µl of Sage Quinn's AdvantageTM Medium with Hepes + 5% HSA-solution medium will be placed on top of the membrane (outlet chamber). After 30 min of incubation in a humidified incubator (37°C), 500 µl of medium, containing the selected spermatozoa, will be retrieved from the upper side of the membrane (retrieval chamber). An amount of 400 µl will be necessary for the IUI procedure.
Density Gradient CentrifugationOther
The gradient columns will be prepared by placing 1 ml 80% gradient media in a centrifuge tube and an additional 1 ml of 40% gradient layered on top. The raw semen sample will be placed on top of the gradient (1ml semen/gradient tube) and centrifuged at 300xg for 20 minutes. The sperm pellet will be collected and washed 2 times for 5 min at 800xg in Sage Quinn's AdvantageTM Medium with Hepes + 5% HSA-solution. The resulted pellet will be resuspended in the washing solution in a volume that will provide at least 1x106 forward motile spermatozoa in 400 µl, as this amount is necessary for IUI procedure.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Cumulative live birth rate after 3 consecutive IUIsTime frame: 9 months following IUI
Locations
1 site in 1 country. Site status is shown where the registry gives one.
UZ Brussel CRG
Brussels, Belgium · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.