Live Birth Rate After Sperm Selection Using ZyMōt Multi (850µL) Device for Intra Uterine Insemination

Evaluation of Live Birth Rate After Sperm Selection Using Microfluidic Technology (ZyMōt Multi (850µL) Sperm Separation Device) for Intra Uterine Insemination.

Last checked: Nov 20, 2026Latest source record: Jan 30, 2024 (this record)Source: ClinicalTrials.govMethods & limitations

RecruitingPivotal-lookingRandomized with 240 participants. This is a heuristic, not a regulatory label.

Status

Recruiting

Enrollment

240

Planned (sponsor's estimate)

Start

Jan 10, 2024

Primary completion

Dec 2026

Study completion Dec 2027

Sponsor

Lead sponsor
Universitair Ziekenhuis BrusselAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Nov 22, 2023

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
Quadruple (participant, care provider, investigator, outcomes assessor)
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 36 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

This single centre interventional pilot randomized control study intends to compare two methods of sperm preparation for couples referred for Intra Uterine Insemination (IUI) procedure. Couples will be randomly allocated to one of the two sperm selection methods: Density Gradient Centrifugation (DGC, standard) or ZyMōt Multi (850µL) device (treatment) groups. The study will compare the live birth rate (number of live births per number of IUI procedures) between the treatment and standard groups.

Conditions

  • Infertility
  • Fertility Disorders

Interventions

  • ZyMōt Multi (850µL)Device

    An amount of 850 µl untreated semen sample will be loaded into the inlet chamber with a help of a sterile insulin-type syringe. A volume of 750 µl of Sage Quinn's AdvantageTM Medium with Hepes + 5% HSA-solution medium will be placed on top of the membrane (outlet chamber). After 30 min of incubation in a humidified incubator (37°C), 500 µl of medium, containing the selected spermatozoa, will be retrieved from the upper side of the membrane (retrieval chamber). An amount of 400 µl will be necessary for the IUI procedure.

  • Density Gradient CentrifugationOther

    The gradient columns will be prepared by placing 1 ml 80% gradient media in a centrifuge tube and an additional 1 ml of 40% gradient layered on top. The raw semen sample will be placed on top of the gradient (1ml semen/gradient tube) and centrifuged at 300xg for 20 minutes. The sperm pellet will be collected and washed 2 times for 5 min at 800xg in Sage Quinn's AdvantageTM Medium with Hepes + 5% HSA-solution. The resulted pellet will be resuspended in the washing solution in a volume that will provide at least 1x106 forward motile spermatozoa in 400 µl, as this amount is necessary for IUI procedure.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Cumulative live birth rate after 3 consecutive IUIsTime frame: 9 months following IUI

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • UZ Brussel CRG

    Brussels, Belgium · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.