All In MedTech

Device Trial Radar · NCT06122116

Investigating Orthobiologics After PRP and Photobiomodulation for Knee Osteoarthritis

Investigating Orthobiologics After Platelet-Rich Plasma and Photobiomodulation Treatment of Knee Osteoarthritis

Last checked: Nov 19, 2026Latest source record: Nov 8, 2024 (this record)Source: ClinicalTrials.govMethods & limitations

Terminated

Status

Terminated

Enrollment

33

Actual

Start

Oct 13, 2023

Primary completion

Oct 10, 2024

Study completion Oct 10, 2024

Sponsor

Sponsor type
Federal agency
Collaborators
The Geneva Foundation
First posted
Nov 8, 2023

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Treatment
FDA-regulated device
Yes
Who can join
All sexes, from 18 years, up to 64 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

This research assesses the effects that Photobiomodulation Therapy (PBMT) has on Intra-articular administered Plasma-Rich Platelet (PRP) injections for Knee Osteoarthritis (KOA) treatment through evaluations of synovial and serum inflammatory and reparative biomarkers. A comparison of Physical Therapy (PT) vs PT + PRP vs PT + PBMT vs PT + PRP + PBMT for KOA treatment is made. The relationship between self-reported pain and functionality and treatment mechanisms is analyzed along with an analysis of the intersectionality between participant self-reported pain and functionality and medicine markers across treatment groups. These aims seek to inform current treatment practices in treating KOA and returning Active-Duty Service Members to duty readiness.

Conditions

  • Knee Osteoarthritis

Interventions

  • Physical TherapyOther

    The PT treatment participants receive in this study will be standard of care; that is, the PT treatment regimen will not be standardized across study participants and/or dictated by study-specific criteria. Participants will be referred to the Physical Therapy Department at the Madigan Army Medical Center (MAMC). Number of PT treatments will be documented on a follow-up Chart Review.

  • Platelet-Rich Plasma InjectionBiological

    PRP injection procedures will follow current clinical recommendation and standard operating procedures. Prior to the injection, the area will be sterilely prepared and anesthetized with either ethyl chloride spray or lidocaine (limited to the cutaneous and subcutaneous layer, so as not to alter the synovial contents). Then, the participant will receive LP-PRP injection in the affected knee area under ultrasound guidance. Qualified study providers will inject 2-5cc LP-PRP using an 18-gauge 1/5-inch needle for both aspiration and subsequent injection. Study providers will select the injection portal they are most comfortable with, in order to achieve an accurate intra-articular injection. The PRP injection procedure is expected to take approximately one hour.

  • Photobiomodulation TherapyDevice

    PBMT is delivered with the LightForce® XPi 25W device through the Smart Hand Piece technology. PBMT will be delivered at 6 J/cm\^2 and applied in a circular pattern to the knee area.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Kellgren Lawrence Classification System (KL)Time frame: Baseline
  2. Defense and Veterans Pain Rating Scale (DVPRS)Time frame: Baseline
  3. Defense and Veterans Pain Rating Scale (DVPRS)Time frame: Daily, for 6 weeks

61 more outcomes with a free account

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Madigan Army Medical Center

    Tacoma, Washington

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.