All In MedTech

Device Trial Radar · NCT06095466

Cirrhotic Cardiomyopathy Based on Point-of-care Echocardiography, Biomarkers and Histology

Diagnosis and Pathogenetic Mechanisms in Cirrhotic Cardiomyopathy Based on Point-of-care Echocardiography, Biomarkers and Histology

Last checked: Nov 19, 2026Latest source record: Nov 13, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

150

Planned (sponsor's estimate)

Start

Jul 15, 2023

Primary completion

Oct 15, 2027

Study completion Nov 15, 2027

Sponsor

Sponsor type
Academic, hospital or other
First posted
Oct 23, 2023

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 65 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Cirrhotic cardiomyopathy is associated with increased risk of complications like hepatorenal syndrome, refractory ascites, impaired response to stressors including sepsis, bleeding or transplantation, poor health related quality of life and increased morbidity and mortality. Left ventricular diastolic dysfunction (LVDD) is associated with risk of hepatorenal syndrome (HRS) , septic shock. , heart failure in the perioperative period following liver transplantation, and after trans-jugular intrahepatic portosystemic shunt (TIPS) insertion . The echocardiographic E/e' ratio is a predictor of survival in LVDD, with multiple studies, including prospective data from our Centre.

Conditions

  • Cirrhotic Cardiomyopathy
  • Cirrhosis, Liver
  • Cardiac Disease

Interventions

  • Echocardiographic assessmentDevice

    M mode, cross sectional and pulsed wave Doppler Echocardiographic examinations will be performed using a with a 2.5 MHz wide angle phased array transducer. Patients will be laid in left lateral position and examined in standard parasternal long and short axis and apical views. Short axis recordings will be performed at the level of the papillary muscles. M mode tracings will be recorded at the level of the papillary muscles and the aortic valves, with 2 -D guidance. LV wall thickness and cavity diameters will be measured by M mode, through the largest diameter of the ventricle, if possible, both in diastole and systole. Using the cross-sectional images as a guide, the M mode tracing of the left ventricle will obtained to calculate measurements according to the recommendations of American Society of Echocardiography.

  • Histopathology and ImmunohistochemistryDiagnostic test

    In patients who do not survive, we will take a trucut core biopsy from the ventricular myocardium, using ultrasound guidance. Cardiac tissue slices preserve the heterogeneous structure and multicellularity of the myocardium and allow its functional characterization. However, in this protocol, only those patients who consent to autopsy or those who consent to most mortem biopsy will be sampled for cardiac histology in CCM. Thus samples for histology and immunohistopathology will be available in only a few patients. For the immunohistochemistry study, the sections will be collected on the poly-L-lysine covered slides and dried in a thermostat, at 37°C, for 24 hours, for increasing the adherence of the biological material to the histological slide.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Determine the prevalence of cirrhotic cardiomyopathy in critically ill patients with cirrhosisTime frame: At Enrollment

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Dr. Madhumita Premkumar

    Sector-12, Chandigarh, India · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.