Device Trial Radar · NCT05868759
Assessment of Preoperative and Postoperative Ankle Kinematics
Last checked: Nov 20, 2026Latest source record: May 22, 2023 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
24
Actual
Start
Jul 28, 2020
Primary completion
May 13, 2021
Study completion Jun 1, 2022
Sponsor
- Lead sponsor
- Istituto Ortopedico RizzoliAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- May 22, 2023
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Not applicable (single group)
- Model
- Single group
- Masking
- None
- Primary purpose
- Diagnostic
- FDA-regulated device
- No
- Who can join
- All sexes, from 40 years, up to 80 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The objective is to study the joint kinematics of the prosthetic implant, in terms of translation, rotation, Range of motion and proprioception, in patients treated for prosthetic replacement of the ankle, quantitatively and under physiological load conditions.
Conditions
- Ankle Osteoarthritis
Interventions
Roentgen Stereophotogrammetric Analysis (RSA)Radiation
Roentgenstereophotogrammetric analysis (RSA) is a radiographic technique, highly accurate both to evaluate the primary stability of the implant, then the micromovements between bone and implant prosthetic, both for the evaluation of the kinematics of the prosthetic components. The RSA technique in dynamics is able to obtain, with patient in motion, a series of radiographic frames in sequence in two projections, which are captured simultaneously. Each pair of orthogonal projections corresponds to a specific moment of the movement carried out by the patient and will be used to obtain, through dedicated software, a reconstruction three-dimensional instant defined "RSA scenes".
Delos Postural Proprioceptive System (computerized oscillating platform)Device
The Delos Postural Proprioceptive System uses electronic tilting tables (on a single axis or three axes) with high frequency that allows very short stop and reversal times that allow both to study the proprioception and the patient's response to the modification of movement of the inclined plane
Modified Star Excursional Balance TestsDiagnostic test
The Star Excursional Balance Test (SEBT) is a clinical test designed for the evaluation of dynamic physical performance of the tibiotarsica. The first literary references date back to 1998 and the test, remaining in balance with the ankle in the studio, the achievement of the maximum possible distance with the contralateral foot along well-defined axes.
Inertial sensors Xsens MVNDevice
The inertial motion acquisition system Xsens MVN is easy to use and economic to detect the movement of different anatomical districts. MVN is based on inertial sensors in miniature through communication solutions combined with advanced fusion algorithms sensors, using hypotheses of biomechanical models. This MVN system is a system of inertial kinematic measurement of the whole body, which incorporates synchronized data. Instant graphic output is provided, including angles of motion articular.
American Orthopaedic Foot and Ankle Score (AOFAs)Other
American Orthopaedic Foot and Ankle Score (AOFAs) is a clinical trial commonly used in scientific literature which serves to assess, in terms of value from 0 to 100, the autonomy, pain, stability, ankle alignment and back foot of the patient.
Visual Analogue Scale (VAS)Other
The Visual Analogue Scale (VAS) is a visual representation of the extent of pain that the patient subjectively warns. The VAS is represented by a 10 cm long line in the original version validated, with or without notches at each centimeter. One end indicates the absence of pain and corresponds to 0, the other end indicates the worst pain imaginable and corresponds to 10.
12-Item Short Form Survey (SF-12)Other
The 12-Item Short Form Survey (SF-12) is a self-reported outcome measure assessing the impact of health on an individual's everyday life.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Roentgenstereophotogrammetric analysisTime frame: 9 months
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Rizzoli Orthopaedic Institute
Bologna, BO, Italy
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.