All In MedTech

Device Trial Radar · NCT05784103

Comparison of Tissue Oxygenation Measurement Using Multimodal Devices

Measurement of Oxygen Saturation in Healthy Human Volunteers Before, During, and After Hyperemic Events Using Multi-Modal Techniques: Spatial Frequency Domain Imaging, Transcutaneous Oxygen Measurement, Pulse Oximeter, and Apple Watch

Last checked: Nov 19, 2026Latest source record: Nov 29, 2023 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedResults posted on the registry

Status

Completed

Enrollment

20

Actual

Start

Mar 9, 2022

Primary completion

Jul 7, 2022

Study completion Jul 7, 2022

Sponsor

Lead sponsor
Indiana UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Mar 24, 2023

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Other
FDA-regulated device
Yes
Who can join
All sexes, from 18 years, up to 65 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

Pulse oximeters are common medical devices used to measure blood oxygen saturation (SpO2). These devices are either stand-alone or integrated into physiologic monitoring systems, using 2 wavelengths of light to determine SpO2. With recent advances in technology, Spatial Frequency Domain Imaging (SFDI) uses a range of light wavelengths from red to near-infrared (NIR), and smartphones such as Apple Watch, and transcutaneous oximetry TCOM now have pulse oximetry capabilities. Since it is possible that most patients could utilize this technology, we sought to assess the accuracy, reliability, and usability of these oximeters and compare outcomes. In this study, a cohort of 20 healthy volunteers above the age of 18 including males and females of different skin colors will be assessed at the same site and data will be compared. We aim to provide a set of data that will support the clinical and scientific community and identify more than one reliable skin oxygen measurement modality.

Conditions

  • Oxygen Saturation

Interventions

  • Clarifi ModulumDevice

    During consenting period, the Modulim equipment will be calibrated and setup ready for scanning. Subject's volar aspect of the thumb along with the palm surface will be ready to target the optical camera head. Actual scanning takes less than 60 seconds. The images will be processed offline. During processing 3-5 different regions of interest will be taken to measure the oxygen parameters such as tissue oxygen saturation, oxy-hemoglobin, deoxy-hemoglobin, superficial hemoglobin, and sub-surface hemoglobin.

  • Perimed PeriFlux 5000Device

    Transcutaneous oxygen monitoring (TCOM or TcpO2) is a noninvasive, clinically-approved method to obtain skin oxygen levels. The method is quantitative, and measures oxygen delivery to the skin from underlying tissue. Before positioning the electrode, an adhesive fixation ring will be placed on the dry skin on the volar aspect of the thumb and an electrolyte as a contact liquid will be filled half and the probe is aligned into it by rotating clock-wise to fasten it. Recording will be started and waited for the oxygen level to stabilize and a fixed value will be recorded. The probe will be heated to about 45oC. Although this device has other options, only the measurement of O2 will be performed using this device.

  • Apple Watch Oxygen SensorDevice

    The apple watch is equipped with green, red, and infrared LEDs that shine light onto the blood vessels in the wrist, with photodiodes measuring the amount of light reflected back. Apple's algorithms use this information to calculate the color of the blood, which is an indication of how much oxygen is in the blood. Bright red blood is well oxygenated, while darker blood has less oxygen. This can measure blood oxygen levels between 70 and 100 percent. Most healthy people have blood oxygen levels that range from 95 to 100 percent. The apple watch sensor will be positioned on the user's preferred wrist.

  • Innovo iP 900APDevice

    The pulse oximeter enables transcutaneous monitoring of the oxygen saturation of hemoglobin in arterial blood. In this study, volar aspect of thumb and index finder of the subject will be used to measure blood oxygen saturation.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Device-wise Comparison of Tissue Oxygenation MeasurementTime frame: Visit 1, up to 2 hours in duration
  2. Male vs Female Comparison of Tissue Oxygenation MeasurementTime frame: 1 visit, 2hrs
  3. Skin Type Based Comparison of Tissue OxygenationTime frame: 1 visit, 2hrs duration

Locations

2 sites in 1 country. Site status is shown where the registry gives one.

  • Indiana University, School of Medicine

    Indianapolis, Indiana

  • Surya C. Gnyawali, University of Pittsburgh, UPMC

    Pittsburgh, Pennsylvania

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.