Evaluation of the Safety and Usability of the M3T FERTIGO® System and Its Calibration

Last checked: Nov 20, 2026Latest source record: Oct 24, 2023 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

20

Actual

Start

Sep 14, 2022

Primary completion

Apr 26, 2023

Study completion Apr 26, 2023

Sponsor

Lead sponsor
Instituto Valenciano de Infertilidad, IVI VALENCIAAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Jun 30, 2022

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
Female only, from 18 years, up to 40 years

Summary

As written by the sponsor on the registry.

We have developed a new minimally invasive system for endometrial dating, that allows the physician to monitor, capture, project and analyze the actual morphology and maturity of the endometrial surface, at any given time. A time series of such indications provides an assessment regarding the pace of development by which the endometrium is maturing during a relevant cycle. FERTIGO®'s method for endometrial dating has been validated in swine and ex-vivo human samples, where image analysis of tissues has been compared with traditional endometrial dating techniques. The comparison yielded calibration means and correlation between FERTIGO®'s dating and the traditional dating methods. Thus, M3T FERTIGO®'s system is designed to enable the determination of the actual physiological cycle date, in good correlation with the indirect (endometrial thickness and hormones level) and delayed known methods (histopathology). To this end, a high quality, low magnification (X2-X4) image of the endometrium surface should be acquired, stored and analyzed. This trial will evaluate, on the one hand, the safety and usability of the FERTIGO® device and, on the other hand, calibrate it by evaluating image quality. Both safety and usability will be measured through questionnaires answered by the participants (adverse events and satisfaction) and by the physicians (satisfaction), respectively, considering the introduction of the device, its use, and its removal.

Conditions

  • Infertility, Female

Interventions

  • IMAGE CAPTURE SESSIONDevice

    The M3T FERTIGO® is an instrument to be used by a certified gynecologist and in particular by an IVF expert physician in order to observe and monitor the state of the endometrium lining of patients. The M3T device serves as a "mini hysteroscope" capable of magnification, capturing images and optional image processing thereof. The M3T enables to acquire in-vivo, magnified images of the endometrium surface, to identify key morphological parameters, calculate their attributes and statistics thereof and compare those for different acquisition images and to some "standard" tissue state tracks. One may then attempt to predict the Embryo transfer optimal timing, based on this analysis.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. To evaluate the safety and usability of the M3T for endometrium image captureTime frame: 1 month

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Ivi Valencia

    Valencia, Spain

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.