Device Trial Radar · NCT05287646
Quantifying Bone and Skin Movement in the Residual Limb of Individuals With Transtibial Amputation Using Dynamic Stereo X-Ray
Last checked: Nov 19, 2026Latest source record: Nov 16, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
21
Planned (sponsor's estimate)
Start
Jan 5, 2024
Primary completion
Feb 28, 2027
Study completion Mar 31, 2027
Sponsor
- Lead sponsor
- VA Office of Research and DevelopmentFederal agency
- Sponsor type
- Federal agency
- Collaborators
- Rutgers University; University of Rhode Island
- First posted
- Mar 18, 2022
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- None
- Primary purpose
- Basic science
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Individuals with lower extremity amputation are often challenged by complications that arise from poor prosthetic fit, including movement of the residual limb in the socket, known as pistoning. Pistoning can lead to gait instability, skin problems, and pain. Different prosthetic suspension systems have been developed to decrease this motion, including elevated vacuum suspension, which utilizes a pump to draw air from the socket. However, scientific analyses to understand the movement between the limb and socket have yet to be performed with a high level of accuracy. This study will use a state-of-the art imaging technique, known as dynamic stereo x-ray, to quantify the 3D movement of the residual limb in the socket. It is hypothesized that dynamic stereo x-ray will be a sensitive method to measure differences in residual limb movement between 2 different socket suspension techniques: suction and elevated vacuum suspension. This information is critical for advancing prosthetic treatments to reduce secondary conditions and degenerative changes that result from poor prosthetic fit.
Conditions
- Amputation, Lower Limb
Interventions
Suction Suspension FirstDevice
Participants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system inactive (traditional suction). Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system active.
Elevated Vacuum Suspension FirstDevice
Participants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system active. Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system inactive.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Changes in dynamic residual tibia kinematics between suspension techniquesTime frame: 4 weeks post socket fit
- Changes in dynamic skin deformation of the residual limb between suspension techniquesTime frame: 4 weeks post socket fit
Locations
1 site in 1 country. Site status is shown where the registry gives one.
VA NY Harbor Healthcare System, New York, NY
New York, New York · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.