Relationship Between the Depth of Anesthesia and Auditory Evoked Potentials (P3a)

Continuous Monitoring of the P3a Response During General Anesthesia Using the Rough Auditory Stimuli Coupled to the Analysis of Frontal EEG Signal

Last checked: Nov 19, 2026Latest source record: Aug 19, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Withdrawn

Status

Withdrawn

Enrollment

0

Actual

Start

Dec 2023

Primary completion

Dec 2024

Study completion Dec 2024

Sponsor

Lead sponsor
Assistance Publique - Hôpitaux de ParisAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
INSERM UMR-942, Paris, France; Laboratoire de Mécanique des Solides, École polytechnique; M3DISIM Inria Université Paris-Saclay
First posted
Mar 16, 2022

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The interest of perioperative cerebral monitoring and in particular electroencephalography (EEG) to reduce neurological and cognitive damage in surgery has been the subject of abundant research and corresponds to a crucial issue. There is increasing evidence to suggest that inadequate (overdosed) anesthesia for patient characteristics and intraoperative hemodynamic instability is associated with an increased risk of complications including postoperative cognitive dysfunction and postoperative mortality. However, these devices have many limitations in use, in particular their consideration of the muscle component of the electrical signal collected.There are other identifiable EEG signals that can be used to assess the depth of anesthesia, in particular auditory evoked potentials (AEPs). The so-called rough sound waves correspond to a formulation composed of the rapid repetition of acoustic segments, at a frequency of 30 to 150 Hz.This frequency (whether sound or light) induces a temporal activation that captures attention and provokes unpleasant sensations and avoidance strategies when perceived by a subject. This project aims at overcoming the interaction of the muscular electrical signal by evaluating the electrophysiological response (auditory evoked potentials) to particular sound stimuli, called "rough", thus underpinning the understanding of the mechanisms of neurosensory integration and attention during a state of loss of consciousness or altered consciousness. The hypothesis proposed for this study is the following: the P3a wave (positive wave collected on the EEG during auditory evoked potentials) is altered during general anesthesia, in frequency and amplitude, and thus is indicative of the depth of the anesthetic state.

Conditions

  • General Anesthesia

Interventions

  • Electroencephalogram recordingDevice

    Brain function monitoring using a Sedline® module (Masimo corporation) to evaluate the state of the brain under anesthesia

  • Auditory stimulationOther

    Monotonous sounds are sent via binaural headphones: a standard item and a distractor item (rough sound). Each stimulus lasts about 300 ms and they are separated by 1.5 to 2 seconds between them; the deviant sound/standard sound ratio is fixed between 1/5 and 1/6.

  • Transcranial DopplerDevice

    Measurement of cerebral blood flow velocity (CFV) with use of Transcranial Doppler ultrasonography. For all patients, CFV (unit cm/s) will be collected over four distinct periods: 1/ baseline or during pre-oxygenation at inspired oxygen fraction (FiO2) of 21% in awake patients; 2/ during anesthetic induction; 3 /deep sleep; 4/ recovery period.

  • Near-infrared spectroscopyDevice

    Continuous measurement of cerebral oxygen saturation (SO2) with Near-infrared spectroscopy (NIRS). For all patients, SO2 (%) will be collected over four distinct periods: 1/ baseline or during pre-oxygenation at FiO2 of 21% in awake patients; 2/ during anesthetic induction; 3 /deep sleep; 4/ recovery period.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Duration of the P3a subcomponent of the P300Time frame: Duration of the surgical intervention or interventional neuroradiology procedure (maximum 1 day)
  2. P3a amplitudeTime frame: Duration of the surgical intervention or interventional neuroradiology procedure (maximum 1 day)
  3. P3a frequencyTime frame: Duration of the surgical intervention or interventional neuroradiology procedure (maximum 1 day)

1 more outcomes with a free account

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • AP-HP, Lariboisière Hospital, Department of Anesthesiology and Intensive Care

    Paris, France

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.