Device Trial Radar · NCT05235321

Automated Applanation Tonometry

Last checked: Nov 20, 2026Latest source record: Sep 11, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

TerminatedResults posted on the registryPivotal-lookingRandomized with 118 participants. This is a heuristic, not a regulatory label.

Status

Terminated

Enrollment

118

Actual

Start

Nov 21, 2022

Primary completion

May 31, 2024

Study completion May 31, 2024

Sponsor

Lead sponsor
Duke UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Feb 11, 2022

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
Yes
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Goldmann Applanation Tonometry (GAT) is considered the clinical gold standard for eye pressure measurements and yet it is known to be a subjective measurement with limited repeatability and limited portability. The purpose of this study is to develop an automated and objective method for performing applanation tonometry using standard ophthalmic equipment as well as using 2 portable prototypes.

Conditions

  • Glaucoma
  • Glaucoma, Suspect

Interventions

  • Standard GATDevice

    Standard Goldmann Applanation Tonometry (GAT): this is the standard method for IOP measurement in clinical practice

  • Fixed force GATDevice

    An investigational device similar to standard GAT

  • Upright applanating prototypeDevice

    An investigational device, prism used in standard and fixed-force GAT is attached to a portable device

  • Supine Applanating PrototypeDevice

    An investigational device, prism used in standard and fixed-force GAT is attached to a portable device performed in the supine position

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Intraocular Pressure (IOP)Time frame: Single study visit, approximately 20 minutes

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Duke Eye Center

    Durham, North Carolina

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.