Device Trial Radar · NCT05198921
The Effectiveness of Repetitive Transcranial Magnetic Stimulation for Spastic Diplegia Cerebral Palsy
Last checked: Nov 20, 2026Latest source record: Sep 19, 2024 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Status unknown
Enrollment
30
Planned (sponsor's estimate)
Start
Jan 2025
Primary completion
May 2025
Study completion Jun 2025
Sponsor
- Lead sponsor
- Universitat de LleidaAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jan 20, 2022
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- Quadruple (participant, care provider, investigator, outcomes assessor)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 6 years, up to 12 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Cerebral palsy describes a group of permanent disorders of the development of movement and posture, causing activity limitation that are attributed to non-progressive disturbances that occurred in the developing fetal or infant brain. Nowadays, CP is not fully curable, and physiotherapy should be used in conjunction with other interventions such as oral drugs, botulinum toxin type A, continuous pump-administered intrathecal baclofen, orthopaedic surgery and selective dorsal rhizotomy. However, several systematic reviews conclude that there is low evidence that these invasive therapies are more effective than placebo. Repetitive transcranial magnetic stimulation (rTMS) is a type of neuromodulatory technique through magnetic impulses. The effect of rTMS depends on the frequency of the emitted electromagnetic field; low frequencies (≤1 Hz) lead to an inhibition of neuronal electrical activity at the stimulation site, while high frequencies (≥3 Hz) cause neuronal depolarization. The objective of the project is to evaluate the effectiveness of a repetitive Transcranial Magnetic Stimulation (rTMS) protocol, as an adjunct treatment to neurorehabilitation to improve gross motor function and quality of life in school-age children with spastic diplegia-type infantile cerebral palsy.
Conditions
- Cerebral Palsy, Spastic
Interventions
repetitive Transcranial Magnetic StimulationDevice
To apply the rTMS will be used the device Neuro-MS/D Variant-3 therapeutic advanced (Neurosoft, Russia) with double cone shape coil. The coil will be placed at Cz according to 10-20 system. The rTMS protocol will be: Train frequency - 10 Hz Train duration - 10 sec Inter train interval - 50 seconds Number of train - 25 \------------------------------------- Total pulses - 2500 Total session duration - 1500 seconds
sham repetitive Transcranial Magnetic StimulationDevice
Neuro-MS/D magnetic stimulator (Neurosoft, Russia) with Neuro-MS.NET software will be used. The synchronous sound will be performed using monitor speaker connected to magnetic stimulator via trigger unit and located near discharging coil. The 10-Hz electrical stimulation will be given trough electrodes fixed on the head along the front edge of the coil to mimic the sensation
Primary outcomes
What the sponsor says the trial is designed to measure.
- Change in Gross Motor Function by the Gross Motor Function-66Time frame: baseline, one month, two months, three months and six months.
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Claudia Arumi
Lleida, Lleida, Spain
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.