Improvement of Immunologic and Molecular Techniques for the Diagnosis and Follow-up of Patients With Thrombotic Thrombocytopenic Purpura
Last checked: Nov 20, 2026Latest source record: Feb 11, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Active, not recruiting
Enrollment
500
Planned (sponsor's estimate)
Start
Oct 13, 2022
Primary completion
Nov 14, 2025
Study completion Jun 2026
Sponsor
- Lead sponsor
- Fundación Española de Hematología y HemoterapíaAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Sep 16, 2021
Design
- Study type
- Observational
- FDA-regulated device
- No
- Who can join
- All sexes, from 0 years, up to 99 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The lack of ADAMTS13 is the only biological marker that is specific for aTTP diagnosis8 and the assessment of ADAMTS13 is of clinical importance because it is essential for the rapid differential diagnosis between aTTP and other TMA. Furthermore, monitoring of ADAMTS13 activity is useful to ensure biological remission (ADAMTS13 levels \> 10%) as well as predicting relapses. Due to the high mortality rate of aTTP, treatment should be started as soon as the disease is suspected, sometimes even before confirmation with the ADAMTS13 test results. This situation may lead to misdiagnose some patients and leave them without the appropriate treatment. In conclusion, ADAMTS13 activity assay is crucial for an early diagnosis and optimal management of acute aTTP and any delay in ADAMTS13 results will have a negative impact on the diagnosis, treatment and prognosis of the patient. There are currently 2 techniques available for the ADAMTS13 activity determination, the fluorescence resonance energy transfer (FRET) and the Technozym chromogenic enzyme-linked immunosorbent assay (ELISA). Both are considered reference methods but they require considerable skill because they are highly manual and this increases the risk of error. Furthermore, these methods are time-consuming, not widely available and, in case of the ELISA method, it requires a new calibration at each run. The inter-laboratory variability is also a challenge and therefore a validation and/or interpretation method could be needed. Recently, a new and first fully automated HemosIL AcuStar ADAMTS13 Activity assay (Instrumentation Laboratory, Bedford, Massachusetts, United States) has been developed. HemosIL AcuStar ADAMTS13 Activity assay is a two steps chemiluminescent immunoassay (CLIA) with an analytical time of 33 minutes for the quantitative measurement of ADAMTS13 activity in human-citrated plasma on the ACL AcuStar analyser. The immunoassay uses the GST-VWF73 substrate in combination with magnetic particles for rapid separation and chemiluminescence technology detection. The ADAMTS13 present in the plasma sample cleavages the GST-VWF73 substrate and the detection of the generated fragments is based upon an isoluminol-labelled monoclonal antibody that specifically reacts with the cleaved peptide. The emitted light is proportional to the ADAMTS13 activity in the sample. This new ADAMTS13 assay method has been compared with the other two available techniques in two different studies. First, Favresse et al. published the results of the comparison between Technozym activity ELISA assay and the new HemosIL AcuStar chemiluminescent assay. On the other hand, Valsecchi et al. have recently published the results of validation of this new technique in comparison with ELISA and FRETS in 176 samples. Both studies conclude that the new chemiluminescent ADAMTS13 activity assay showed a good correlation and excellent clinical performance for the diagnosis of severe ADAMTS13 deficiency with the FRETS-VWF73 assay and a commercial ELISA when considering only ADAMTS13 activity values below 10% (the internationally accepted cut-off for a diagnosis of severe ADAMTS13 deficiency typical of aTTP). Finally, Stratmann et al. have just published another study comparing the HemosIL AcuStar chemiluminescent assay with two commercially available ADAMTS13 assay kits using 24 paired test samples derived from 10 consecutively recruited patients13 and their results corroborate the previously published data suggesting that the AcuStar assay could be a valuable and accurate tool for ADAMTS13 activity testing and aTTP diagnostic. In this context, a unique opportunity to validate this new technique is generated, both retrospectively with our already available data from frozen samples and also in the context of a large prospective study. This will be the first study worldwide testing HemosIL AcuStar method in real clinical practice aTTP population (Spanish and Portuguese aTTP populations) with the aim to standardize the diagnosis and follow-up methodology for the disease.
Conditions
- Acquired Thrombotic Thrombocytopenic Purpura
Interventions
ADAMTS13 Activity AssaysDevice
In this study the measurement of ADAMTS13 activity will be assessed with three different commercial kits: 1. HemosIL AcuStar ADAMTS13 Activity Assay (Instrumentation Laboratory, Bedford, Massachusetts, United States) 2. ELISA, DG-EIA ADAMTS13 Activity (Diagnostic Grifols®, Spain) 3. FRETS-VWF73 for ADAMTS13 Activity Assay Three kits will be used with all patients.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Correlation of a new diagnostic test and standard testTime frame: At diagnosis of patients with acquired thrombotic thrombocytopenic purpura (aTTP).
6 more outcomes with a free account
Locations
6 sites in 2 countries. Site status is shown where the registry gives one.
Centro Hospitalar e Universitario de Coimbra
Coimbra, Coimbra District, Portugal
5 more study sites with a free account
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.