All In MedTech

Device Trial Radar · NCT04755257

Development of the Muscle Architecture Based Isokinetic Strength Assessment Position for Shoulder Rotator Muscles

Last checked: Nov 19, 2026Latest source record: Feb 16, 2021 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

52

Actual

Start

Nov 15, 2019

Primary completion

Jan 15, 2020

Study completion May 15, 2020

Sponsor

Lead sponsor
Ankara Yildirim Beyazıt UniversityAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Feb 16, 2021

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
No
Who can join
Male only, from 18 years, up to 25 years

Summary

As written by the sponsor on the registry.

Today, the most commonly used position is the seated position with 45° of shoulder abduction (Abd) in the scapular plane, known as the most functional isokinetic assessment of shoulder-rotator strength (1). However, considering the architectural feature of the rotator muscles, a position where the maximum sarcomere length is obtained, in which the maximum muscle strength is produced, has not been investigated. Ward et al. showed that the shoulder position, in which the sarcomere length of the muscles was between 2.0 - 2.6 µm, was 25⁰ Abd and 20⁰ external rotation (ER) as a result of their study on the rotator cuff muscles architecture (2). The test position selected in isokinetic measurements is the main factor for outcome measurements and the repeatability of the measurements directly depends on the selected position (3). This study was planned to investigate the effects of the position where the shoulder is at 25⁰ Abd and 20⁰ ER to develop the most suitable isokinetic strength evaluation position based on muscle architecture for shoulder rotator muscles.Using IsoMed 2000 device (D. \& R. Ferstl GmbH, Hemau, Germany) we conducted the isokinetic test of concentric (CON) and eccentric (ECC) shoulder internal (IR) and external (ER) strength at the angular velocity of 60˚/s in both Method I (scapular position) and Method II (25⁰ Abd and 20⁰ ER). There were seven days between the testing sessions, and both tests were conducted at the same time of day. The same examiner with experience in performing isokinetic testing with IsoMed 2000 tested all subjects in both testing sessions

Conditions

  • Muscle Architecture
  • Shoulder
  • Isokinetic
  • Rotator Muscle

Interventions

  • Isokinetic testDevice

    Using IsoMed 2000 device (D. \& R. Ferstl GmbH, Hemau, Germany) we conducted the isokinetic test of concentric (CON) and eccentric (ECC) shoulder internal (IR) and external (ER) strength at the angular velocity of 60˚/s in both Method I (scapular position) and Method II (25⁰ Abd and 20⁰ ER). There were seven days between the testing sessions, and both tests were conducted at the same time of day. The same examiner with experience in performing isokinetic testing with IsoMed 2000 tested all subjects in both testing sessions.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. concentric shoulder internal rotation peak torque and peak torque/weight at the angular velocity of 60˚/s in Method I (scapular position)Time frame: Six month
  2. concentric shoulder external rotation peak torque and peak torque/weight at the angular velocity of 60˚/s in Method I (scapular position)Time frame: Six month
  3. concentric shoulder internal rotation peak torque and peak torque/weight at the angular velocity of 60˚/s in Method II (25⁰ Abd and 20⁰ ER)Time frame: Six month

5 more outcomes with a free account

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Ankara Yıldırım Beyazıt University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation

    Ankara, Etlik, Turkey (Türkiye)

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.