Corneal Biomechanical Analysis Using Brillouin Microscopy

Last checked: Nov 19, 2026Latest source record: Oct 1, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Enrolling by invitation

Status

Enrolling by invitation

Enrollment

220

Planned (sponsor's estimate)

Start

Jun 1, 2021

Primary completion

Jul 2027

Study completion Dec 2027

Sponsor

Lead sponsor
The Cleveland ClinicAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
University of Maryland
First posted
Oct 22, 2020

More device trials from this sponsor

Design

Study type
Observational
FDA-regulated device
Yes
Who can join
All sexes, from 18 years, up to 60 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The objective of this study is to measure the Brillouin biomechanical properties in keratoconic corneas and characterize biomechanical alterations that occur after corneal procedures that inherently strengthen or weaken the cornea by evaluating the change in Brillouin metrics before and after treatments.

Conditions

  • Keratoconus
  • Keratoconus, Unstable
  • Keratoconus, Stable

Interventions

  • Brillouin microscopyDevice

    The Brillouin clinical instrument is comprised of three parts: a human interface, a laser-scanning confocal microscope, and an etalon-based spectrometer. The human interface is a modified ophthalmic slit-lamp instrument with chin support and headrest. The light source is a single longitudinal mode CW laser at 780 nm. A polarizing beam splitter and quarter-wave plate assembly sends the laser beam to the human interface. To focus light into the eye, a long-working distance microscope objective is used. Brillouin scattered light from the eye is collected with a single-mode optical fiber. For spectral analysis, a two-stage VIPA-etalon spectrometer configured with the cross-axis cascade principle and the spectrum is measured on a EM-CCD camera.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change in Brillouin MetricsTime frame: Difference between baseline and 3 months after intervention

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Cleveland Clinic Cole Eye Institute

    Cleveland, Ohio

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.