Device Trial Radar · NCT04406961
Endoscopic Antegrade Sphincterotomy (ASD) Versus Standard Sphincterotomy
Last checked: Nov 19, 2026Latest source record: Jan 7, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Completed
Enrollment
1,521
Actual
Start
Jan 1, 2020
Primary completion
Dec 21, 2024
Study completion Dec 21, 2025
Sponsor
- Lead sponsor
- Military Medical Clinical Center of the Southern Region, UkraineAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- May 29, 2020
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- None
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years, up to 102 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This study compares endoscopic transpapillary antegrade sphincterotomy developed by Dr. Dovbenko (Antegrade Sphincterotomy Dovbenko, ASD) with conventional pull-type endoscopic sphincterotomy (EST) in patients undergoing transpapillary interventions for various indications, including biliary stone disease, major duodenal papilla stenosis, choledocholithiasis, and other conditions requiring access to the biliary and/or pancreatic ducts. The ASD technique is performed using a dedicated sphincterotome designed by Dr. Dovbenko. Both the technique and the device are patented in Ukraine (Patent No. UA 117987C2, 2019). This instrument enables selective incision of only the circular muscle layer of the sphincter of Oddi, thereby preserving its sphincteric function and minimizing trauma to the duodenal wall. The primary objective of the study is to evaluate the relative risk of procedure-related complications, including bleeding, perforation, post-ERCP pancreatitis, and the need for cholecystectomy.
Conditions
- Choledocholithiasis
- Papillary Stenosis
- Biliary Obstruction
- Gallstone Disease
- External Biliary Fistula
- Malignant Biliary Obstruction
- Benign Biliary Strictures With Current or Prior Biliary Obstruction
Interventions
Endoscopic transpapillary antegrade sphincterotomy developed by Dr. Dovbenko.Procedure
Sph. Oddi consists of a longitudinal and circular smooth muscle layers. Circular muscle fibers form the pancreatic and duodenal parts. Anatomical justification was cutting of only the circular layer of sph Oddi by special sphincterotome. Papillary stenosis and stenosis terminal part of common bile duct due to damage only circular layer sph Oddi. Anterograde direction and hooked form of sphincterotome (endoscopic antegrade sphincterotomy- ASD) allows to capture only need layer and control depth. Also ASD was performed patient with SOD (I-III) with preservation of the longitudinal muscular layer sph Oddi and septum of papilla.
The antegrade sphincterotome developed by Dr. Dovbenko.Device
A device is represented by a teflon catheter in the distal part of which a double tube of variable shape is created. The proximal part of the ASD sphincterotome consists of a handle, and a metal wire is located inside the teflon catheter for connection to an electrosurgical unit. On the distal part, the teflon catheter is formed of a double tube length is 10 to 35 mm. The metal wire exits the catheter at a distance 10 to 35 mm from the tip and enters into the tip the second teflon tube. The distal part of the knife is formed shape a hook. A metal cutting wire is located between two tubes. Moving the handle the metal wire is shifted. Pushing the metal wire or approaching in the distal part the second tube sets the depth of cut. The incision is made by moving on guidewire in bile duct. The power settings vary.
Endoscopic sphincterotomy.Procedure
Endoscopic standard sphincterotomy aims at opening bile duct or pancreatic duct by cutting the papilla and sphincter muscles. After deep bile duct cannulation, the standard sphincterotome is retracted until one fourth to one half of the wire length is exposed outside the papilla. The sphincterotome is slightly bowed so that the wire is in contact with the roof. The incision is made lifting the sphincterotome against the papillary roof using the elevator and up-down controls while applying short bursts of current. The power settings vary. The extent of the sphincterotomy is limited by the length of the intraduodenal portion of the common bile duct.
The standard sphincterotome.Device
The standard sphincterotome, the Erlangen "pull-type" model, consists of a catheter containing a cautery wire exposed 15 to 25 mm near the tip of the instrument. The leading tip distal to the wire, the "nose," is 5 to 10 mm in diameter. After deep bile duct cannulation, the sphincterotome is retracted slowly, until one fourth to one half of the wire length is exposed outside the papilla. The sphincterotome is slightly bowed so that the wire is in contact with the roof. The incision is made by lifting the sphincterotome against the papillary roof using the elevator and up-down controls while applying short bursts of current. The power settings vary.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Composite incidence of major procedure-related adverse eventsTime frame: Up to 30 days after the procedure.
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Oleg Dovbenko
Odesa, Odesa Oblast, Ukraine
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.