All In MedTech

Device Trial Radar · NCT04095767

Assessing Safety and Performance of the ANA Catheter System, Combined With a Stent Retriever in Acute Ischemic Stroke

Prospective, Single-Arm, Multi-center Study to Assess the Safety and Performance of the ANA Catheter System, in Combination With a Stent Retriever in Patients With Acute Ischemic Stroke

Last checked: Nov 19, 2026Latest source record: Jul 2, 2021 (this record)Source: ClinicalTrials.govMethods & limitations

Terminated

Status

Terminated

Enrollment

74

Actual

Start

Sep 21, 2019

Primary completion

Jun 15, 2021

Study completion Jun 15, 2021

Sponsor

Lead sponsor
Anaconda Biomed S.L.Not on our public-company list
Sponsor type
Industry
First posted
Sep 19, 2019

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 85 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The ANA catheter system (may also be designated as "ANA system", "ANA 18 -002" or "ANA device") is a distal access catheter designed to assist in neurovascular procedures by facilitating the insertion and guiding of other devices (i.e. retrieval devices and intravascular catheters) and restricting blood flow at the target position. It is a sterile, single-use, disposable intravascular device comprised of two coaxial catheters (delivery catheter and funnel catheter) consisting of sections of variable stiffness. The funnel catheter is comprised of a radiopaque nitinol braid (self-expanding funnel), covered by a continuous silicone coating that, when deployed, provides local and temporary flow restriction. The delivery catheter has a hydrophilic coating to reduce friction during use and a radiopaque marker on the distal end. Both catheters have Luer lock hubs on their proximal end. The proposed study has been designed to collect prospective clinical evidence to compare the Anaconda ANA device to similar devices used for guiding and supporting stent retrievers during neurothrombectomy procedures. The protocol has been designed to replicate the patient population enrolled in prior studies of similar devices. The primary endpoint will be ability of the investigational device to facilitate stentriever deployment and neurothrombectomy in the anterior circulation, with successful reperfusion defined as achieving a modified Thrombolysis in Cerebral Infarction (mTICI) score of ≥2b in the target vessel with ≤3 passes of the investigational device without the use of rescue therapy. Follow-up at 24h, Day 5 (+/- 12 h) or discharge, whichever comes first and at 90 days will allow documentation of the clinical outcome of the neurothrombectomy procedure as a whole and detect any device related and other complications, making use of the ANA device for distal access.

Conditions

  • Stroke, Ischemic

Interventions

  • NeurothrombectomyDevice

    Intra-arterial recanalization therapy or mechanical thrombectomy (MT) is a therapeutic option for patients who are not candidates for t-PA or in whom t-PA has failed. MT is performed by means of various devices (Merci Revive, Penumbra, etc.). There are currently two major approaches to MT: the so-called stent retrievers (used with or without a balloon catheter), and catheters used for direct aspiration (manual with syringe or by aspiration pump via distal access catheters \[DACs\]). Moreover, both techniques can be combined. MT may be performed following IV t-PA, as a stand alone therapy, or in conjunction with IA thrombolysis.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. modified Thrombolysis in Cerebral Infarction (mTICI) scoreTime frame: At end of neurothrombectomy
  2. Occurrence of serious Adverse Device EffectsTime frame: Up to 90 days

Locations

9 sites in 1 country. Site status is shown where the registry gives one.

  • Hospital Vall d'Hebron

    Barcelona, Spain

  • Hospital Clínic de Barcelona

    Barcelona, Spain

  • Hospital Universitari de Bellvitge

    Barcelona, Spain

6 more study sites with a free account

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.