All In MedTech

Device Trial Radar · NCT04082273

Comparison of Femto-laser and Manually Created Clear Corneal Incisions During Cataract Surgery

A Single Center, Randomized Control Study to Compare Efficacy and Safety of Femto-laser Created Clear Corneal Incisions with Manually Created Clear Corneal Incisions During Cataract Surgery

Last checked: Nov 20, 2026Latest source record: Nov 4, 2024 (this record)Source: ClinicalTrials.govMethods & limitations

Completed

Status

Completed

Enrollment

80

Actual

Start

Aug 26, 2019

Primary completion

Jul 15, 2024

Study completion Jul 15, 2024

Sponsor

Lead sponsor
Ziemer Ophthalmic Systems AGNot on our public-company list
Sponsor type
Industry
First posted
Sep 9, 2019

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Treatment
FDA-regulated device
No
Who can join
All sexes, from 40 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

The aim of this study is to test the hypothesis, that in terms of Surgically Induced corneal Astigmatism (SIA), Higher-order Aberrations (HOA), and wound geometry the femtosecond clear corneal incisions (CCIs) created during cataract surgery are not inferior when compared to manual CCIs. The potential risks associated with application of the femtosecond laser in this study are no greater or in most cases less than those associated with the standard manual cataract surgical procedure, and the potential benefits (such as precision and reproducibility) are greater than with the standard manual cataract surgery. Therefore, the risk-to-benefit ratio is very low, such that the potential benefits for a subject participating in this study exceed the potential risks

Conditions

  • Cataract

Interventions

  • Femtosecond Laser for Cataract SurgeryDevice

    Cataract Surgery on study eye according to conventional procedure, with the exception of three steps (Capsulotomy, Lens Fragmentation and Clear Corneal Incisions) which are performed with a Femtosecond Laser in the laser treatment group. Equipment uesd for measurements is the same for both groups and in line with the normal equipment used for the conventional cataract treatment

  • Conventional Cataract SurgeryOther

    Cataract surgery will be performed conventionally, this means the clear corneal incisions will be performed manually by a blade, the capsulorhexis will be performed manually by a hook, and the lens extraction will be done by phacoemulsification

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Change from baseline (pre-operative) Surgically Induced corneal Astigmatism (SIA) measured by means of corneal topography Galilei G2Time frame: Baseline = Pre-operative, Follow-up = 12 days, 4 weeks and 6 weeks after surgery

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Augenklinik ORASIS AG

    Reinach, Canton of Aargau, Switzerland

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.