All In MedTech

Device Trial Radar · NCT04024293

Intraocular Pressure Measured by a Novel Sensing Contact Lens Versus Tonometry

A Prospective Single Center Open Label Study Assessing Intraocular Pressure Measurements Using a Novel Sensing Contact Lens-based Device as Compared to Standard Tonometry, in Open Angle Glaucoma and Ocular Hypertensive Patients

Last checked: Nov 20, 2026Latest source record: Apr 30, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

Recruiting

Status

Recruiting

Enrollment

12

Planned (sponsor's estimate)

Start

Oct 1, 2025

Primary completion

May 2026

Study completion May 2026

Sponsor

Lead sponsor
Sensimed AGNot on our public-company list
Sponsor type
Industry
First posted
Jul 18, 2019

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Not applicable (single group)
Model
Single group
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

While elevated intraocular pressure (IOP) is no longer part of the definition of glaucoma it remains the sole proven modifiable risk factor for the onset and progression of glaucoma. IOP is known to vary with the time of day as well as with daily activities. The importance of the nycthemeral IOP pattern for successful management of glaucoma has been well documented, especially for patients who experience visual loss despite apparently normal and/or controlled IOP during office hours. The current way of assessing nycthemeral IOP fluctuation is to perform repeated discrete tonometry measurements, once per hour in the best cases. Since its development in the 50s, Goldmann applanation tonometry (GAT) has remained the gold standard method for measuring IOP, despite its limitations. However, tonometry may be an imperfect method for measuring changes in IOP because it allows only snapshot and non-continuous measurements, it is not physiologic and disturbs the sleep architecture. There have been many efforts in the past decades to search for an ambulatory and frequent method to monitor IOP for 24 hours. In this context, Sensimed AG has recently developed a sensing contact lens-based device intended to measure IOP over 24 hours, the Goldfish (GF). First-in-man data obtained with this device showed agreements between IOP measured by GF and values obtained by standard tonometry in the same eye, comparable to literature results for routinely used tonometry devices. However, this pilot study included 9 subjects only with improvable safety, tolerability and efficacy profiles. The main goal of this study is to assess IOP measurements with the GF and compare the values with those obtained by standard tonometry in patients with open angle glaucoma (OAG) and ocular hypertension (OHT).

Conditions

  • Glaucoma
  • Ocular Hypertension

Interventions

  • Goldfish (GF)Device

    The GF lens (SCL) will be place on participant's eye for a 24h IOP recording session

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. GF IOP measurement as compared to IOPTime frame: 24 hours

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • Clinique Montchoisi

    Lausanne, Canton of Vaud, Switzerland · Recruiting

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.