Repeatability, Reproducibility and Comparison of Cirrus OCT, RTVue OCT, MS-39 OCT, and Insight 100 VHFDU

Repeatability and Reproducibility of Carl Zeiss Meditec Cirrus HD OCT 5000, Optovue RTVue OCT, CSO MS-39 OCT and ArcScan Insight 100 Very High-frequency Digital Ultrasound and Comparison Between Devices

Last checked: Nov 19, 2026Latest source record: Apr 26, 2022 (this record)Source: ClinicalTrials.govMethods & limitations

Suspended

Status

Suspended

Enrollment

242

Planned (sponsor's estimate)

Start

Sep 1, 2022

Primary completion

Dec 1, 2023

Study completion Dec 1, 2023

Sponsor

Lead sponsor
London Vision ClinicAcademic, hospital or other
Sponsor type
Academic, hospital or other
Collaborators
Carl Zeiss Meditec AG
First posted
Mar 22, 2018

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Non randomized
Model
Parallel
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
Yes
Who can join
All sexes, from 21 years, up to 70 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

The purpose of this study is to evaluate the repeatability and reproducibility of corneal, epithelial, and LASIK flap thickness using the Carl Zeiss Meditec Cirrus HD OCT 5000, Optovue RTVue OCT, CSO MS-39 OCT, and ArcScan Insight 100 very high-frequency digital ultrasound arc-scanner.

Conditions

  • Corneal Thickness Measurement
  • Epithelial Thickness Measurement
  • LASIK Flap Thickness Measurement
  • SMILE Cap Thickness Measurement

Interventions

  • ArcScan Insight 100 very high-frequency digital ultrasoundDevice

    The ArcScan Insight 100 VHF digital ultrasound scanner can measure individual layers within the cornea with very high precision, as well as being able to image the interior of the eye including the chamber between the iris and the cornea, the lens and other structures behind the iris. The ArcScan Insight 100 device is a digital ultrasound scanner, meaning that it uses ultrasound waves to measure parameters of the eye. The Insight examination involves the patient sitting in front of the ultrasound unit and looking through a disposable goggle-like eyepiece at a light source. Warm sterile balanced saline solution (like natural tears) are used to fill the space between the light source and the eye, to allow ultrasound transmission. There is no contact between the instrument and the eye other than being immersed in this water bath.

  • Carl Zeiss Meditec Cirrus HD OCT 5000Device

    The Cirrus HD OCT 5000 uses high definition spectral domain optical coherence tomography (OCT) to measure anatomical structures of the eye. OCT is non-contact and uses light, rather than ultrasound, to obtain cross-sectional images. An OCT scan involves the patient sitting in front of the device, placing their chin on a chin-rest and fixating on a light source. Nothing comes into contact with the eye and the patient is only aware of the instrument rotating in front of them.

  • Optovue RTVue OCTDevice

    The Optovue RTVue OCT uses high definition Fourier/spectral domain optical coherence tomography (OCT) to measure anatomical structures of the eye. OCT is non-contact and uses light, rather than ultrasound, to obtain cross-sectional images. An OCT scan involves the patient sitting in front of the device, placing their chin on a chin-rest and fixating on a light source. Nothing comes into contact with the eye and the patient is only aware of the instrument rotating in front of them.

  • CSO MS-39 OCTDevice

    The CSO MS-39 OCT uses high definition Fourier domain optical coherence tomography (OCT) to measure anatomical structures of the eye. OCT is non-contact and uses light, rather than ultrasound, to obtain cross-sectional images. The MS-39 also includes a Placido topographer within the device to simultaneously obtain a measurement of the shape (curvature) of the front surface of the cornea, which is then combined with the OCT thickness measurement to generate the shape of the back surface of the cornea. An OCT scan involves the patient sitting in front of the device, placing their chin on a chin-rest and fixating on a light source. Nothing comes into contact with the eye and the patient is only aware of the instrument rotating in front of them.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Repeatability and reproducibility of Cirrus HD OCT 5000 corneal scans in normal eyes (standard deviation)Time frame: 10 minutes (5 minutes per observer)
  2. Repeatability and reproducibility of RTVue OCT corneal scans in normal eyes (standard deviation)Time frame: 10 minutes (5 minutes per observer)
  3. Repeatability and reproducibility of MS-39 OCT corneal scans in normal eyes (standard deviation)Time frame: 10 minutes (5 minutes per observer)

7 more outcomes with a free account

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • London Vision Clinic

    London, United Kingdom

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.