Device Trial Radar · NCT03381677
Pedicle Osteotomy for Stenosis Trial
Last checked: Nov 19, 2026Latest source record: Aug 3, 2020 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Suspended
Enrollment
344
Planned (sponsor's estimate)
Start
Oct 26, 2017
Primary completion
Oct 26, 2022
Study completion Oct 26, 2024
Sponsor
- Lead sponsor
- Innovative Surgical DesignsNot on our public-company list
- Sponsor type
- Industry
- First posted
- Dec 22, 2017
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Double (participant, investigator)
- Primary purpose
- Treatment
- FDA-regulated device
- Yes
- Who can join
- All sexes, from 40 years, up to 80 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
This is a pivotal Randomized Clinical trial to compare the safety and effectiveness of the Pedicle Lengthening Osteotomy Procedure with implantation of the Altum® Device to open surgical decompression and Transforaminal Lumbar Interbody Fusion (TLIF) in patients with symptomatic, one or two level lumbar spinal stenosis (LSS) and one level grade I degenerative spondylolisthesis requiring surgical treatment.
Conditions
- Lumbar Spinal Stenosis
- Spondylolisthesis, Grade 1
- Neurogenic Claudication
Interventions
Pedicle Lengthening Osteotomy with Altum® DeviceDevice
Decompressive surgery via Pedicle lengthening osteotomy using Altum Device. Altum is intended for pedicle lengthening to correct degenerative lumbar spinal stenosis in the presence of a grade 1 degenerative spondylolisthesis. The Altum bone saw is designed for creating an osteotomy at the base of each pedicle. The Altum implant is designed for distraction of the pedicle osteotomy and for lengthening of the pedicles. Altum is appropriate for skeletally mature adults with symptomatic stenosis at one or two levels between L2-L5.
ControlDevice
Decompressive surgery via open surgical decompression and Transforaminal Lumbar Interbody Fusion (TLIF) using either a midline or paramedian incision with implantation of bilateral pedicle screws (4 screws) and rods (2 rods) and an interbody fusion cage (1 PEEK fusion cage, coated or uncoated): 1. DePuy Synthes Expedium® 5.5 System, Stryker Xia 5.5 System, Medtronic CD Horizon Solera 5.5 Systemor Innovative Surgical Designs True Spinal Fixation System; and 2. DePuy Synthes Concord TLIF cage, Stryker UniLIF TLIF cage, Medtronic Capstone TLIF cage or Meditech Talos TLIF cage.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Zurich Claudication Questionnaire (ZCQ)Time frame: 24 months
- No reoperationsTime frame: Index level
- Adjacent level surgeryTime frame: 24 months
2 more outcomes with a free account
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Rothman Institute
Bryn Mawr, Pennsylvania
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.