All In MedTech

Device Trial Radar · NCT03347669

A Pilot Study of Small Fiber Neuropathy Prevalence in Fibromyalgia Patients Compared to Healthy Subjects Using Sudoscan®

Last checked: Nov 19, 2026Latest source record: Nov 17, 2026 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedPivotal-lookingRandomized with 100 participants. This is a heuristic, not a regulatory label.

Status

Completed

Enrollment

100

Actual

Start

Nov 6, 2017

Primary completion

Mar 14, 2018

Study completion Mar 14, 2018

Sponsor

Lead sponsor
University Hospital, Clermont-FerrandAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Nov 20, 2017

More device trials from this sponsor

Design

Study type
Interventional
Phase
Not applicable (typical for device studies)
Allocation
Randomized
Model
Single group
Masking
None
Primary purpose
Diagnostic
FDA-regulated device
No
Who can join
All sexes, from 18 years, up to 65 years
Healthy volunteers
Yes

Summary

As written by the sponsor on the registry.

Fibromyalgia (FM) is characterized by chronic diffuse pain and affects 0.5 to 5% of the population, with a higher prevalence in women1. This condition is characterized by joint and muscle pain, also associated with fatigue, migraine, sleeps disorders, depression and irritable bowel syndrome2. The presentation of these various symptoms varies greatly from one patient to another, with great heterogeneity in clinical, physical, social, psychological and therapeutic responses. . A recent parliamentary inquiry report called for recognition of the disease and recommended to build a unified care path for patients; a collective expertise is led by INSERM to help in patient care. Faced with the heterogeneity of FM, several international studies have attempted to identify subgroups of patients based essentially on clinical symptoms of the disease3-8, including a recent Korean study of 313 patients9, which suggested four groups, but with methodological limitations, not taking into account the new criteria10 for evaluating FM. Recent studies have also shown that there is a peripheral neuropathic component in the mechanisms of this pathology, demonstrated by a decrease in the density of the epidermal nerve fibers11-12, called small fiber neuropathy (SFN) neuropathy. It is an attack of small sensory and sympathetic nerve fibers, causing pain, paresthesia as well as disturbances of the autonomous system. Other studies also suggested that a significant proportion of patients diagnosed with fibromyalgia had SFN, demonstrated by cutaneous biopsy13-14 or confocal microscopy of the cornea15. A new device, the Sudoscan®, makes it possible to detect a SFN much simpler, faster and less invasive than the technique of ophthalmology or biopsy. Although this Sudoscan® test has been used extensively in conditions such as diabetes16-19, no study has been used to assess the presence of SFN in FM. The aim of this pilot study is to identify the prevalence of SFN in FM patients, using this new non-invasive device, in order to have a better defined representation of the prevalence of small-fiber neuropathy in an FM population compared to a group of healthy volunteer matched in age, sex, BMI and by menopausal status for women.

Conditions

  • Fibromyalgia

Interventions

  • Sudoscan®Device

    Sudoscan® is a new device that provides rapid, non-invasive and reproducible quantitative assessment of sweat function. It makes it possible to measure the ability of the sweat glands to release chloride ions in response to electrochemical activation and thus to detect the presence of a neuropathy with small fibers. This new device therefore makes it possible to detect an SFN in a much simpler and faster way than the technique of ophthalmology, or biopsy. Sudoscan® has been tested to assess the neuropathies of small nerve fibers in several diseases, in particular diabetes, chemotherapy-induced polyneuropathy, familial amyloid polyneuropathy or Fabry disease. The interest of Sudoscan® lies in the fact that this device is non-invasive and rapid. Its diagnostic value has been compared with other neurophysiological tests.

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Measure of the electrochemical conductance (µS) using Sudoscan®Time frame: at day 1

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • CHU Clermont-Ferrand

    Clermont-Ferrand, France

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.