Device Trial Radar · NCT03290872
Mitral Annuloplasty Rings RCT
Last checked: Nov 21, 2026Latest source record: Sep 25, 2017 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Status unknown
Enrollment
50
Planned (sponsor's estimate)
Start
Sep 2017
Primary completion
Sep 2019
Study completion Sep 2019
Sponsor
- Lead sponsor
- University Health Network, TorontoAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Sep 25, 2017
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Single (participant)
- Primary purpose
- Treatment
- FDA-regulated device
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
Recently published work has suggested that mitral valve annuloplasty ring type may affect the development of post-repair mitral stenosis resulting in adverse intracardiac hemodynamics and poor functional status. However, these results have not been comprehensively determined in a systematic manner on a general mitral valve repair population. As well, an underlying mechanism for these findings is not understood. The investigators hypothesize that mitral valve repair with a complete annuloplasty ring (Carpentier-Edwards Physio II) when compared to repair with a partial annuloplasty ring (Simplici- T) may not necessarily result in elevated mitral gradients consistent with functional mitral stenosis (FMS). Currently no prospective data exists to test the hypothesis that a correctly sized, flexible complete annuloplasty ring has detrimental effects. As 60% of annuloplasty rings used in surgical repair of degenerative mitral valve disease in North America utilizes one of the many forms of complete flexible rings available, this information is urgently required. The investigators will evaluate: 1) the effect on mitral valve hemodynamics, 2) changes to mitral annular, valvular and subvalvular structure and function with 3D echocardiography, and 3) the effect on patient functional capacity at 1 year. If FMS early post repair is a real phenomenon, the investigators hope to better understand the mechanisms through the use of advanced imaging techniques-namely 3D modeling of the mitral valvular apparatus, aortic mitral interactions and LV remodeling.
Conditions
- Degenerative Mitral Valve Disease
Interventions
Carpentier Edwards Physio 2 Complete flexible mitral ringDevice
Mitral valve Annuloplasty Ring repair using a Carpentier Edwards Physio 2 Complete flexible mitral ring
Simplici T Partial flexible mitral annuloplasty ringDevice
Mitral valve Annuloplasty Ring repair using a Simplici T Partial flexible mitral annuloplasty ring
Primary outcomes
What the sponsor says the trial is designed to measure.
- Mean mitral valve gradientTime frame: 1 year
Locations
No sites are listed on the registry yet.
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.