Device Trial Radar · NCT03204513
Impact of Powered Knee-Ankle Prosthesis Leg on Everyday Community Mobility and Social Interaction
Last checked: Nov 19, 2026Latest source record: Apr 22, 2026 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Active, not recruiting
Enrollment
15
Planned (sponsor's estimate)
Start
Dec 2016
Primary completion
Dec 2026
Study completion Dec 2026
Sponsor
- Lead sponsor
- Shirley Ryan AbilityLabAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- Jul 2, 2017
Design
- Study type
- Interventional
- Phase
- Not applicable (typical for device studies)
- Allocation
- Randomized
- Model
- Crossover
- Masking
- None
- Primary purpose
- Device feasibility
- Who can join
- All sexes, from 18 years, up to 80 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
The overall goal of this research is to determine the efficacy of new powered prosthetic devices for individuals with transfemoral amputations. The anticipation is that this will be a high-impact technological intervention with the potential to restore significant functionality to individuals with lower limb amputation and transform the field of lower limb prosthetics. The objective of the proposed clinical trial is to fully evaluate the biomechanical and energetic effects of using PKA prosthesis and quantify functional performance and quality of life changes.
Conditions
- Transfemoral Amputees
Interventions
Vanderbilt Powered Knee-Ankle ProsthesisDevice
The Vanderbilt powered prosthesis is a transfemoral prosthesis with powered and coordinated knee and ankle joints. The Generation 3 prosthesis is actuated by two brushless direct current (DC) motors, providing up to 100 Nm of torque at the knee joint, and with the assistance of a parallel stiffness, up to 200 Nm in plantar flexion at the ankle. Sensors measure knee and ankle joint angles, axial load in the shank, and position and orientation of the prosthesis in space (via a 6-axis inertial measurement unit). An onboard lithium-ion battery provides sufficient energy for approximately 10,000 steps between battery charges. The prosthesis prototype weighs approximately 4.3 kg (9.5 lb), the mass of which is approximately equivalent to the intact limb of a 48 kg (105 lb) person.
Microprocessor (MP) Knee ProsthesisDevice
Participants enrolled will already have their own microprocessor controlled (MP) non-powered knee prostheses as per inclusion criteria. Examples: OttoBock's C-Leg, Ossur's Rheo, Freedom Plie, Endolite Orion,etc.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Change between devices of the Modified Graded Treadmill TestTime frame: Week 6-7 (Post-Training Assessments); Weeks 21-22 (Post-Training Assessment)
- Change in Biomechanical Assessment [Gait Parameters and Surface Electromyography (EMG) Activation] Between DevicesTime frame: Week 6-7 (Post-Training Assessments); Weeks 21-22 (Post-Training Assessment)
Locations
1 site in 1 country. Site status is shown where the registry gives one.
Shirley Ryan AbilityLab
Chicago, Illinois
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.